Objective: To analyze the influence of 3-mm high abutments with different shapes (cylindrical abutment vs. wide abutment) on marginal bone-level changes (bone loss and bone remodeling). The influence of abutment shape on implant success, probing pocket depth (PPD), and bleeding on probing (BoP) was studied as secondary objectives.
Materials And Methods: Patients with a partially edentulous area requiring fixed dental prostheses by two implants in the posterior mandible or maxilla were included. The implants were 1 mm subcrestally placed, and osseointegration healing was submerged. Three-mm high abutments with two different shapes were randomly placed in second-stage surgery: cylindrical abutments (cylindrical group) and wide abutments (wide group). Marginal bone-level changes were measured using parallelized periapical radiographs at abutment placement, at definitive prosthesis placement, and at 1, 3, 6, and 12 months after loading. PPD and BoP were likewise measured at the control visits.
Results: Sixty-four dental implants in 25 patients were included. Statistically significant differences were found in bone-level changes. The cylindrical group exhibited less mean marginal bone remodeling (MBR) and marginal bone loss (MBL) than the wide group (p < .05). Moreover, the cylindrical group showed significantly less BoP (p < .05).
Conclusion: Abutment shape had a significant influence upon marginal bone-level changes during the first 12 months. Cylindrical abutments caused less MBR and MBL than wide abutments. More clinical studies involving longer follow-ups and analyzing other abutment modifications are needed to improve our understanding of how abutments can affect peri-implant tissue stability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.14130 | DOI Listing |
: Vertical atrophy of the maxilla has traditionally been treated with sinus lift procedures and implant placement, performed in one or two surgical stages. Subsequently, the transcrestal sinus lift technique was introduced, offering distinct advantages in terms of indications and reduced morbidity. Most recently, short implants have emerged as a valid alternative to these procedures, even in cases of severe horizontal resorption, allowing for direct placement in many cases.
View Article and Find Full Text PDFDentomaxillofac Radiol
January 2025
Department of Stomatology, Division of Periodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil.
Objectives: This meta-research assessed methodologies used for evaluating peri-implant marginal bone levels on digital periapical radiographs in randomised clinical trials published between 2019 and 2023.
Methods: Articles were searched in four databases. Data on methods for assessing peri-implant marginal bone levels were extracted.
J Craniofac Surg
November 2024
Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Korea.
Background: Aesthetics is a crucial consideration in the anterior region, alongside dental implant survival and marginal bone loss (MBL). Bone-level implants are advantageous in the esthetic zone as they create a natural emergence profile with the use of customized abutments. This study aimed to assess the esthetic outcomes of internally submerged, tapered, bone-level dental implants and to evaluate associated alveolar bone changes.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
Department of Pediatrics Dentistry and Orthodontics, Faculty Odonto-Stomatology, Can Tho University of Medicine and Pharmacy, Can Tho City, Vietnam.
Aim: This study aimed to evaluate the impact of a combination of immediate implant placement with maxillary sinus augmentation (MSA) solely using platelet-rich fibrin (PRF) on guided bone regeneration.
Materials And Methods: An interventional before-after (pre-post) study design was used with 30 dental patients (≥18 years of age; 14 males and 16 females) with initial bone heights ranging between 4 and 6 mm. Following the general check-up and the creation of a study model, the planned implant location demonstrated an external right maxilla diameter of more than 5 mm, thereby validating the cone-beam computed tomography (CBCT) radiograph.
J Prosthodont
January 2025
Department of Conservative Dentistry and Endodontics, Sri Ramachandra Dental College and Hospital, Chennai, India.
Purpose: Biomimetic agents are being researched for their potential to stimulate bone formation and boost bone-implant contact. The objective of this study was to assess how osseointegration of dental implants is impacted by platelet-rich fibrin.
Materials And Methods: The present study was a randomized clinical trial with a split mouth design.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!