This prospective observational study aimed to evaluate whether lung fluids, assessed by lung ultrasonography and transthoracic electrical bioimpedance (TEB), may be influenced by the presence of a haemodynamically significant patent ductus arteriosus (hsPDA) in very preterm infants during the transitional period. Infants < 32 weeks of gestational age (GA) admitted to the neonatal intensive care units of IRCCS AOU Bologna and Niguarda Metropolitan Hospital of Milan (Italy) underwent a daily assessment of a lung ultrasound score (LUS) and of a TEB-derived index of thoracic fluid contents (TFC) during the first 72 h after birth. Echocardiographic scans were simultaneously performed to evaluate the concomitant ductal status (hsPDA vs. restrictive or closed duct). The correlation between LUS, TFC, and the ductal status was tested using generalized estimating equations. Forty-six infants (median GA: 29 [interquartile range, IQR: 27-31] weeks; median birth weight: 1099 [IQR: 880-1406] g) were included. At each daily evaluation, the presence of a hsPDA was associated with significantly higher LUS and TFC compared with a restrictive or closed ductus (p < 0.01 for all comparisons). These results were confirmed significant even after adjustment for GA and for the ongoing modality of respiratory support. Conclusion: Even during the first 72 h of life, the presence of a hsPDA determines a significant increase in pulmonary fluids which can be non-invasively detected and monitored over time using lung ultrasonography and TEB. What is Known: • Lung ultrasonography provides a non-invasive assessment of lung fluids and is widely used in neonatal settings. • In preterm infants, the persistence of a haemodynamically significant patent ductus arteriosus (hsPDA) over the first weeks can negatively affect pulmonary outcomes. What is New: • The presence of aan hsPDA is associated with increased lung fluids since early postnatal phases. • Lung ultrasonography and transthoracic electrical bioimpedance can effectively monitor lung fluid clearance in preterm infants with a hsPDA during the transitional period, with potential clinical implications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10570199PMC
http://dx.doi.org/10.1007/s00431-023-05106-wDOI Listing

Publication Analysis

Top Keywords

patent ductus
8
ductus arteriosus
8
lung fluids
8
preterm infants
8
infants transitional
8
transitional period
8
impact patent
4
arteriosus non-invasive
4
non-invasive assessments
4
assessments lung
4

Similar Publications

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.

View Article and Find Full Text PDF

Background: Delays in diagnosing rare genetic disorders often arise due to limited awareness and systemic challenges in primary care. This case highlights the importance of a holistic approach to patient care, encompassing timely detection and comprehensive evaluation of clinical features.

Methods: We report the case of a 21-year-old Ecuadorian male with facial and hand dysmorphias, cardiomegaly, pulmonary hypertension, and patent ductus arteriosus (PDA).

View Article and Find Full Text PDF

Background Maternal diabetes mellitus (DM) is a known risk factor for congenital heart diseases (CHDs), which are of significant concern to infants born to diabetic mothers. Compared to newborns born to non-diabetic mothers, infants born to diabetic mothers had a higher overall risk of developing congenital malformations. This association has a complex pathophysiology that includes genetic predispositions, metabolic abnormalities, and environmental factors during key stages of fetal development.

View Article and Find Full Text PDF

Background: Congenital cardiac defects are defined in cases with the deletion of the short arm of chromosome 5 and the duplication of the long arm of chromosome 4. Septal defects and patent ductus arteriosus are among the most common defects reported in the literature.

Case: We reported on a case with a complex congenital cardiac defect, dysmorphic facial features, cat-like cry, hypotonia, hyporeflexia, weak swallowing and sucking, limb anomalies, and bilateral undescended testicles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!