Background Breathing motion management is the key to delivering stereotactic body radiation therapy (SBRT) for liver lesions. This study aimed to compare the dosimetric parameters of liver SBRT using two different techniques: free breathing and breath hold. Method The study included 11 patients with liver metastases or hepatocellular carcinoma who underwent liver-directed SBRT. A dosimetric comparison was performed using dose-volume histogram analysis, evaluating parameters such as the maximum dose to 5 cc of bowel volume, mean liver dose (MLD), and liver V20 and V30. Statistical analyses were performed to compare results. Results The findings revealed that the breath hold technique resulted in significantly lower doses to the bowel and smaller volumes of normal liver tissue receiving 20 Gy (V20) and 30 Gy (V30) than the free breathing. Although there was no statistically significant difference in the MLD between the two techniques, the breath hold technique resulted in a lower MLD. Conclusion This dosimetric comparison study suggests that the breath hold technique is associated with lower radiation exposure to the bowel and normal liver tissues. Although this may not be feasible for all patients, it may be an appropriate procedure for selected individuals. Further research is needed to validate these findings in different patient populations and explore their impact on clinical outcomes and patient-reported quality of life.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10344598PMC
http://dx.doi.org/10.7759/cureus.40382DOI Listing

Publication Analysis

Top Keywords

breath hold
20
dosimetric comparison
12
free breathing
12
hold technique
12
comparison study
8
breathing breath
8
stereotactic body
8
body radiation
8
radiation therapy
8
technique lower
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!