"Faceless kidney": CT sign of renal duplicity.

J Comput Assist Tomogr

Published: October 1986

A CT sign of renal duplicity is described. In kidneys with either bifid renal pelvis or complete duplication of the collecting system, a transverse CT section obtained at the mid pole or junction of the fused upper and lower pole cortical moieties may reveal a "faceless" renal appearance lacking vascular or collecting system elements. Recognition of this finding allows a correct diagnosis of partial or complete duplication of the renal collecting system and prevents a false impression of an intrarenal mass lesion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

collecting system
12
sign renal
8
renal duplicity
8
complete duplication
8
renal
5
"faceless kidney"
4
kidney" sign
4
duplicity sign
4
duplicity described
4
described kidneys
4

Similar Publications

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

Due to incessant contamination of the groundwater system near the dumpsite in southwestern Nigeria Basement Complex, this study seeks to evaluate the impact of the Odogbo dumpsite on the local groundwater system by integrating geophysical and geochemical methodologies. Aeromagnetic data covering the study area was acquired, processed, and enhanced to delineate basement features that could potentially be passing plumes to the groundwater system. Concurrently, geoelectric methods using 2-D dipole-dipole imaging and vertical electrical sounding (VES) were utilized to characterize the vulnerability indices of the lithologies underlying the dumpsite.

View Article and Find Full Text PDF

This work provides a statistical analysis of four different approaches suggested in the literature for the estimation of an unknown concentration based on data collected using the standard addition method. These approaches are the conventional extrapolation approach, the interpolation approach, inverse regression, and the normalization approach. These methods are compared under the assumption that the measurement errors are normally distributed and homoscedastic.

View Article and Find Full Text PDF

This research was carried out to assess the concentrations of carbon monoxide (CO) and formaldehyde (HCHO) in Edo State, Southern Nigeria, using remote sensing data. A secondary data collection method was used for the assessment, and the levels of CO and HCHO were extracted annually from Google Earth Engine using information from Sentinel-5-P satellite data (COPERNISCUS/S5P/NRTI/L3_) and processed using ArcMap, Google Earth Engine, and Microsoft Excel to determine the levels of CO and HCHO in the study area from 2018 to 2023. The geometry of the study location is highlighted, saved and run, and a raster imagery file of the study area is generated after the task has been completed with a 'projection and extent' in the Geographic Tagged Image File Format (.

View Article and Find Full Text PDF

Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.

Langenbecks Arch Surg

January 2025

Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.

Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.

Methods: Thirty non-diabetic pancreatectomy patients participated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!