Debris resulting from damage to the surface of polyethylene components of total joint replacements has previously been shown to contribute to long-term problems such as loosening and infection. Surface damage has been associated with fatigue processes due to stresses arising from contact between the metal and polyethylene components in these prostheses. In the present study, we used elasticity and finite-element solutions to determine these stresses for total hip replacements with head diameters of twenty-two and twenty-eight millimeters and for a condylar total knee replacement. We also examined the effect on these stresses of using carbon-fiber-reinforced polyethylene instead of plain polyethylene. Stresses associated with surface damage in the tibial component of the total knee replacement were much larger than those in the hip replacements. The analysis of contact stress as a function of thickness of the polyethylene insert for tibial components showed that a thickness of more than eight to ten millimeters should be maintained when possible. The contact stress in the tibial components was reduced most when the articulating surfaces were more conforming in the medial-lateral direction. Contact stresses were much less sensitive to changes in geometry in the anterior-posterior direction. For the hip components, the stresses were lower in the acetabular component of the twenty-eight-millimeter hip replacement than in the twenty-two-millimeter replacement. The use of carbon-fiber-reinforced polyethylene resulted in stresses that were higher by as much as 40 per cent. Because the contact area between articulating surfaces moves during flexion, portions of the surface will be subjected to cyclic stresses. The contact area for the knee replacements in flexion was smaller than for the hip replacements, and the range of the maximum principal stress was larger. Consequently, the combination of the higher stress and the moving contact area is more likely to cause surface damage due to fatigue in tibial components than in acetabular components, which is consistent with clinical observations.

Download full-text PDF

Source

Publication Analysis

Top Keywords

surface damage
12
hip replacements
12
tibial components
12
contact area
12
stresses
9
components
8
components total
8
total joint
8
polyethylene components
8
total knee
8

Similar Publications

Background: Helicobacter pylori (H. pylori), a specific bacterium capable of surviving in the acidic environment of the stomach, has been recognized as a group of causative agents of gastric cancer. Therefore, the development of mucosal vaccines against H.

View Article and Find Full Text PDF

Efficient adsorption behavior of Fe-based ternary magnetic LDHs for naphthalene acetic acid: Role of Fe element.

Environ Res

January 2025

School of Environmental Science and Engineering, Shandong Analysis and Test Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. Electronic address:

Naphthalene acetic acid (NAA) is an auxin plant growth regulator (PGR) and widely used to regulate the growth process of plants. As excessive NAA enter the environment, it damages the ecological environment and endangers human life and health. Layered bimetallic hydroxides (LDHs) are widely used for the adsorption of pollutants due to their large surface area and excellent structural properties.

View Article and Find Full Text PDF

Introducing PES porous membrane to establish bionic autocrine channels: A lubricating, anti-wear antifouling coating.

Mar Pollut Bull

January 2025

Department of Materials Science and Engineering, Dalian Maritime University, Dalian 116026, PR China; Dalian Key Laboratory of Internal Combustion Engine Tribology and Reliability Engineering, Dalian 116026, PR China. Electronic address:

As a global challenge, marine biofouling is causing serious economic losses and adverse ecological impacts. In recent years, a variety of promising and environmentally friendly anti-fouling strategies have emerged, among which the excellent anti-fouling performance of bionic autocrine coatings has been recognized. However, bionic autocrine coatings still suffer from uncontrollable secretion behavior, poor mechanical stability, and poor abrasion resistance.

View Article and Find Full Text PDF

Analysis of potential human accumulation differences and mechanisms of environmental new flame retardants: Based on in vitro experiments and theoretical calculations.

Sci Total Environ

January 2025

Institute of Organic Contaminant Control and Soil Remediation, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095, China. Electronic address:

Hundreds of new flame retardants (NFRs) are widely used, causing environmental pollution and threating human health. In this study, based on the interaction of NFRs and human serum albumin (HSA), we assessed the differences in potential human accumulation of 8 NFRs including 1,2-Dibromo-4-(1,2-dibromoethyl)cyclohexane (TBECH), tetrabromobisphenol A bis(dibromopropyl ether) (TBBPA-DBPE), 2,4,6-tribromophenol (TBP), pentabromophenol (PBP), tri-n-butyl phosphate (TnBP), triphenyl phosphate (TPP), Tri(2-chloroethyl) phosphate (TCEP), and Tri(1,3-dichloro-2-propyl) phosphate (TDCP). All NFRs could bind to HSA and cause slight damage to its structure, suggesting their potential human accumulation ability.

View Article and Find Full Text PDF

Gold (or electrum) in hydrothermal fluid precipitates directly from gold sulfide complex and/or partly via suspended nanoparticles. The hydrothermal fluid contains "invisible gold" that is atomically dispersed in sulfide minerals or as nanoparticles with a size of less than 10 nm. However, the contribution of these gold nanoparticles to the formation of native gold and its alloy with silver (electrum) remains unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!