Background: Staphylococcus aureus sequence type 5 (ST5) is an emerging global threat.

Aim: To characterize the epidemiology of ST5 transmission in the anaesthesia work area.

Methods: The retrospective cohort study analysed transmitted, prophylactic antibiotic-resistant Staphylococcus aureus isolates involving anaesthesia work area reservoirs. Using whole-genome analysis, the epidemiology of ST5 transmission was characterized by reservoir(s) of origin, transmission location(s), portal of entry, and mode(s) of transmission. All patients were followed for at least 30 days for surgical site infection (SSI) development.

Findings: Forty-one percent (18/44; 95% confidence interval: 28-56%) of isolates were ST5. Provider hands were the reservoir of origin for 28% (5/18) of transmitted ST5 vs 4% (1/26) for other STs. Provider hands were the transmission location for 28% (5/18) of ST5 vs 7% (2/26) of other STs. Stopcock contamination occurred for 8% (1/13) of ST5 isolates vs 12% (3/25) of other STs. Sixty-three percent of transmission events occurring between cases on separate operative dates involved ST5. ST5 was more likely to harbour resistance traits (ST5 median (interquartile range) 3 (2-3) vs 2 (1-2) other STs; P < 0.001) and had greater resistance to cefazolin, piperacillin-tazobactam, and/or ciprofloxacin (ST5: 3 (2-3) vs 2 (1-3) other STs; P = 0.02). ST5 was associated with three of six SSIs.

Conclusion: ST5 is prevalent among transmitted, prophylactic antibiotic-resistant isolates in the anaesthesia work area. Transmission involves provider hands and one patient to another on future date(s). ST5 is associated with a greater number of resistance traits and reduced in-vitro susceptibility vs other intraoperative meticillin-resistant S. aureus.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhin.2023.07.003DOI Listing

Publication Analysis

Top Keywords

anaesthesia work
16
st5
14
work area
12
staphylococcus aureus
12
provider hands
12
transmission
8
area transmission
8
aureus sequence
8
sequence type
8
epidemiology st5
8

Similar Publications

Objective: To determine the effects of rapid (1 minute) and slow (10 minutes) intravenous (IV) injection of sodium penicillin on arterial blood pressure in anesthetized horses.

Study Design: Prospective randomized clinical trial.

Animals: A group of 29 client-owned horses of various breeds, 1-20 years old, with body masses of 360-710 kg.

View Article and Find Full Text PDF

Preoperative SGLT-2 inhibitor use and risk of adverse postoperative events: a single-centre retrospective observational study.

Br J Anaesth

January 2025

Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Department of Anesthesiology, Medical Faculty and University Hospital Duesseldorf, Heinrich Heine University Duesseldorf, Duesseldorf, Germany. Electronic address:

View Article and Find Full Text PDF

Get that AED out! The Circadian Dilemma of Public Access Defibrillation.

Resuscitation

January 2025

Department of Anesthesia, Intensive Care and Prehospital Emergency, Maggiore Hospital Carlo Alberto Pizzardi, Bologna, Italy. Electronic address: https://twitter.com/ffsemeraro.

View Article and Find Full Text PDF

Background: Anesthesia depth influences seizure quality in patients undergoing electroconvulsive therapy (ECT). EEG-based neuromonitoring has been shown to detect adequate anesthesia depth for ECT. Anesthesia depth-guided ECT management may therefore be a reliable alternative to the predetermined anesthesia-to-stimulation time interval.

View Article and Find Full Text PDF

Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!