Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Cryoprecipitate (CRY) is widely used for treating acquired hypofibrinogenemia. During our study to determine an optimal preparation method, we noticed that the measurement of fibrinogen concentration in CRY had a risk of overestimation. We analyzed this condition and mechanism.
Study Design And Methods: CRY was prepared from fresh frozen plasma (FFP) under four conditions: A, 30 h thawing time, 2 cycles; B, 24 h thawing time, 2 cycles; C, 30 h thawing time, 1 cycle; and D, 24 h thawing time, 1 cycle. Then, fibrinogen concentrations in CRY and cryosupernatant (CS) were measured by the Clauss method.
Results: Purification (CRY/CRY+CS) and recovery (CRY/FFP) rates in CRY prepared under 2-cycle conditions were higher than those under 1 cycle. However, recovery rates often exceeded 100%, particularly in the case of CRY prepared under A condition, and fibrinogen concentrations calculated by direct measurement were higher than those indirectly calculated from FFP and CS, suggesting an overestimation of fibrinogen values. The level of soluble fibrin monomer complex was considerably higher in CRY prepared under A than under D condition, indicating that CRY adopted a hypercoagulated state. We further found that repeated thawing/freezing increased fibrinogen values as measured by the Clauss method while mechanical vortexing did not.
Discussion: Our findings suggest that direct assessment of fibrinogen contents in CRY prepared by repeated freeze-thawing with a longer thawing period presents a higher risk of overestimation. For the purpose of quality control, we propose an alternative method to indirectly estimate fibrinogen concentrations in CRY from those of CS and FFP.