A novel, to the best of our knowledge, compact, imaging-free, tilted-pulse-front (TPF) pumped terahertz (THz) source based on a LiNbO slab with a small wedge angle (< 8°) and with an echelon microstructure on its input surface has been demonstrated. Single-cycle pulses of more than 40-µJ energy and 0.28-THz central frequency have been generated by 100-mJ, 400-fs pump pulses with 4.1 × 10 efficiency and excellent focusability. The peak electric field value focused by a single parabolic mirror was 540 kV/cm. Using 200-fs-long pump pulses, the efficiency increased to 1.0 × 10, which is in qualitative agreement with the measured increased diffraction efficiency in the velocity matched diffraction order. A further ∼8x increase in efficiency is expected by pumping a cryogenically cooled wedged echelon with appropriate step sizes, better microstructured surface quality, and antireflection coating on both the input and the output sides. THz generation efficiency maxima were found at ∼2.7-mm crystal thickness for both pump pulse durations. The focused THz beam was diffraction limited within 5% accuracy. Compared to conventional THz sources, this setup is very compact, easy to align, can be pumped by larger beam sizes maintaining the high THz generation efficiency, and produces THz pulses with superior focusability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.493198 | DOI Listing |
J Exp Biol
January 2025
Hannover Medical School, Institute of Functional and Applied Anatomy, 30625 Hanover, Germany.
Small mammals have a higher heart rate and, relative to body mass (Mb), a higher metabolic rate than large mammals. In contrast, heart weight and stroke volume scale linearly with Mb. With mitochondria filling approximately 50% of a shrew cardiomyocyte - space unavailable for myofibrils - it is unclear how small mammals generate enough contractile force to pump blood into circulation.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Objective: The objective was to evaluate the relationship between carotid stenting and off-pump coronary artery grafting (CAS-OPCABG) and OPCABG only in patients with asymptomatic severe carotid stenosis.
Methods: This study retrospectively included 669 patients with asymptomatic severe carotid artery stenosis who underwent OPCABG at multiple centers. After propensity score matching for baseline characteristics, the study compared two groups of patients with clinical data, early and midterm death, stroke, and myocardial infarction (MI).
Diabetes Technol Ther
January 2025
Department of Paediatric Diabetes and Endocrinology, John Hunter Children's Hospital, New Lambton Heights, New South Wales, Australia.
To compare glycemic outcomes during and following moderate-intensity exercise (MIE), high-intensity interval exercise (HIE), and resistance exercise (RE) in adolescents with type 1 diabetes (T1D) using a hybrid closed-loop (HCL) insulin pump while measuring additional physiological signals associated with activity. Twenty-eight adolescents (average age 16.3 ± 2.
View Article and Find Full Text PDFJ Pain Res
January 2025
Department of Anesthesiology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, 100043, People's Republic of China.
Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).
Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).
JAMA Cardiol
January 2025
Brigham and Women's Hospital Heart and Vascular Center, Center for Advanced Heart Disease, Harvard Medical School, Boston, Massachusetts.
Importance: The Aspirin and Hemocompatibility Events With a Left Ventricular Assist Device in Advanced Heart Failure (ARIES-HM3) study demonstrated that aspirin may be safely eliminated from the antithrombotic regimen after HeartMate 3 (HM3 [Abbott Cardiovascular]) left ventricular assist device (LVAD) implantation. This prespecified analysis explored whether conditions requiring aspirin (prior percutaneous coronary intervention [PCI], coronary artery bypass grafting [CABG], stroke, or peripheral vascular disease [PVD]) would influence outcomes differentially with aspirin avoidance.
Objective: To analyze aspirin avoidance on hemocompatibility-related adverse events (HRAEs) at 1 year after implant in patients with a history of CABG, PCI, stroke, or PVD.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!