The level of triglyceride (TG) in blood is essential to human health, and hypertriglyceridemia (TG level > 150 mg/dL) would lead to cardiovascular disease and acute pancreatitis that threaten human life. Routine methods for measuring the TG level in blood depend on a lipid panel blood test, which is invasive and not convenient. Here, we use photoacoustic (PA) microscopy to test the PA amplitude of blood solutions (based on hemoglobin powder as well as flowing sheep blood) with different TG concentrations. Interestingly, we observe that the PA amplitude increases with increasing TG concentration in blood solutions, which is attributed to the increase of the Grüneisen coefficient. The preliminary in vitro study shows that the PA methodology is able to detect the TG level down to 450 mg/dL. This finding provides an opportunity for using photoacoustics to noninvasively diagnose hypertriglyceridemia.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.485194DOI Listing

Publication Analysis

Top Keywords

concentration blood
8
photoacoustic microscopy
8
blood solutions
8
blood
7
sensing triglyceride
4
triglyceride concentration
4
blood solution
4
solution photoacoustic
4
microscopy level
4
level triglyceride
4

Similar Publications

Background: The quality of life (QOL) of ovarian cancer patients is often impaired by refractory ascites. Cell-free and concentrated ascites reinfusion therapy (CART) is a palliative treatment for refractory ascites, but adverse events, such as fever, are problematic. Several cytokines have been suggested to be responsible for the adverse events, but they have not been investigated in detail.

View Article and Find Full Text PDF

Effect of intramuscular treatment with different iron dextran dosages and non-inferiority study to gleptoferron.

Acta Vet Scand

January 2025

Department of Veterinary and Animal Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Grønnegårdsvej 2, 1870, Frederiksberg C, Denmark.

Background: Prevention of iron deficiency in suckling piglets by intramuscular injection of a standardized amount of iron dextran or gleptoferron in the first days of life can lead to over- or underdosage with respective health risks. Currently, combined iron products containing an active substance against coccidia are also used on farms. When using a combination product targeting two diseases, an adjustment of the necessary amount of iron to prevent anaemia in the frame of a farm-specific treatment protocol is not possible.

View Article and Find Full Text PDF

Introduction: Preclinical studies have shown that oxygen therapy can improve ischaemic brain tissue oxygen tension, reduce reperfusion injury after revascularisation, promote neuroregeneration and inhibit inflammatory responses potentially exerting a beneficial effect after endovascular treatment (EVT) in patients with acute ischaemic stroke (AIS). However, the optimal fraction of inspired oxygen (FiO) during EVT under general anaesthesia is currently unknown. Therefore, we are conducting a randomised controlled trial (RCT) to evaluate the impact of high-concentration oxygen vs low-concentration normobaric oxygen on early neurological function after EVT.

View Article and Find Full Text PDF

Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study.

Br J Anaesth

January 2025

Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria; Department of Anesthesiology and Intensive Care Medicine AUVA Trauma Center Salzburg, Academic Teaching Hospital of the Paracelsus Medical University, Salzburg, Austria.

Background: Bleeding guidelines currently recommend use of viscoelastic testing (VET) to direct haemostatic resuscitation in severe haemorrhage. However, VET-derived parameters of clot initiation, such as clotting time (CT) and activated clotting time (ACT), might not adequately reflect a clinically relevant interaction of procoagulant and anticoagulant activity, as revealed by thrombin generation assays. The aim of this study was to evaluate the ability of CT and ACT to indicate thrombin generation activity.

View Article and Find Full Text PDF

Objectives: To assess whether the Quantra-Qplus can provide the cutoff values for predicting transfusion thresholds after cardiopulmonary bypass.

Design: Prospective observational study.

Setting: Single-center university hospital.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!