Int J Comput Assist Radiol Surg
January 2025
Department of Medical Biophysics, University of Toronto, Toronto, Canada.
Purpose: During endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.
Methods: X-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment.
J Cardiothorac Surg
January 2025
Department of Thoracic Surgery, The Second Xiangya Hospital of Central South University, Changsha, Hunan, P. R. China.
Background: Paragangliomas are rare neoplasms arising from extra-adrenal chromaffin cells, with mediastinal paragangliomas representing an exceptionally rare subset. This report details the surgical management of a complex mediastinal paraganglioma case, presenting with refractory hypertension and invasion of critical surrounding structures. A comprehensive review of the current literature is included to underscore existing cases, enhance clinical awareness, and share our insights and experience in the diagnosis and treatment of this challenging condition.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Physics "A. Pontremoli", University of Milan & INFN sez. Milano, Milano, Italy. Electronic address:
Purpose: This work aims at investigating, via in-silico evaluations, the noise properties of an innovative scanning geometry in cone-beam CT (CBCT): eCT. This scanning geometry substitutes each of the projections in CBCT with a series of collimated projections acquired over an oscillating scanning trajectory. The analysis focused on the impact of the number of the projections per period (PP) on the noise characteristics.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Radiation Oncology, The Third Affiliated Hospital, Sun Yan-Sen University, Guangzhou 510630, China. Electronic address:
A preliminary study was conducted using electronic portal imaging device (EPID) based dose verification in pre-treatment and in vivo dose reconstruction modes for breast cancer intensity-modulated radiation therapy (IMRT) technique with known repositioning set-up errors. For 43 IMRT plans, the set-up errors were determined from 43 sets of EPID images and 258 sets of cone beam computed tomography images. In-house developed Edose software was used to reconstruct the dose distribution using the pre-treatment and on-treatment (in vivo) EPID acquired fluence maps.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Orthodontics and Craniofacial Biology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands.
Purpose: This study aimed to evaluate the dental and skeletal stability one year after Miniscrew-Assisted Rapid Palatal Expansion (MARPE) by using 3D image data.
Methods: Patients with transverse maxillary deficiency from the age of 16 onwards were enrolled consecutively in this prospective longitudinal cohort study. The MARPE appliance was digitally and individually designed and fabricated.