A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Esophageal biomechanics assessed by impedance planimetry (EndoFLIPTM) in healthy subjects and in patients with eosinophilic esophagitis. Normality values. | LitMetric

Background: active eosinophilic esophagitis is associated with esophageal caliber, distensibility and motility changes that may be reversed with treatment.

Objectives: to study esophageal diameter, distensibility and contractility in healthy subjects compared to patients with eosinophilic esophagitis, both before and after treatment.

Methods: a quasi-experimental study, EndoFLIP™, was used to analyze the esophageal body and esophago-gastric junction (EGJ) in all three groups, and a program was designed to obtain esophageal diameter, distensibility and contractility values.

Results: ten healthy volunteers (24-61 years, six men) and nine patients with eosinophilic esophagitis (21-52 years, seven men) were included. The esophagogastric junction distensibility index was 5.07 mm2/Hg in the control subjects, 2.40 mm2/Hg in the subjects with eosinophilic esophagitis before treatment and 2.46 mm2/Hg after treatment. The distensibility plateau was 20.02 mm, 15.43 mm and 17.41 mm, respectively, and the diameter was 21.90 mm, 17.73 mm and 18.30 mm, showing significant differences (p < 0.05), except between control subjects and patients after treatment (p = 0.079). Repetitive antegrade contractions developed in 90 % of control subjects, 66.7 % of eosinophilic esophagitis patients before treatment and 88.9 % of the latter after treatment (p > 0.05).

Conclusions: esophago-gastric junction distensibility index, distensibility plateau and diameter values were higher in controls than in patients, although six weeks of treatment seems a short period to observe significant changes in esophageal biomechanics. Repetitive antegrade contractions are the predominant pattern in healthy subjects and eosinophilic esophagitis. We provide normality values for esophageal biomechanics, measured by impedance planimetry in our setting.

Download full-text PDF

Source
http://dx.doi.org/10.17235/reed.2023.9560/2023DOI Listing

Publication Analysis

Top Keywords

eosinophilic esophagitis
28
esophageal biomechanics
12
healthy subjects
12
patients eosinophilic
12
control subjects
12
impedance planimetry
8
subjects patients
8
normality values
8
esophageal diameter
8
diameter distensibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!