Background: Automatic segmentation of the choroid on optical coherence tomography (OCT) images helps ophthalmologists in diagnosing eye pathologies. Compared to manual segmentations, it is faster and is not affected by human errors. The presence of the large speckle noise in the OCT images limits the automatic segmentation and interpretation of them. To solve this problem, a new curvelet transform-based K-SVD method is proposed in this study. Furthermore, the dataset was manually segmented by a retinal ophthalmologist to draw a comparison with the proposed automatic segmentation technique.

Methods: In this study, curvelet transform-based K-SVD dictionary learning and Lucy-Richardson algorithm were used to remove the speckle noise from OCT images. The Outer/Inner Choroidal Boundaries (O/ICB) were determined utilizing graph theory. The area between ICB and outer choroidal boundary was considered as the choroidal region.

Results: The proposed method was evaluated on our dataset and the average dice similarity coefficient (DSC) was calculated to be 92.14% ± 3.30% between automatic and manual segmented regions. Moreover, by applying the latest presented open-source algorithm by Mazzaferri . on our dataset, the mean DSC was calculated to be 55.75% ± 14.54%.

Conclusions: A significant similarity was observed between automatic and manual segmentations. Automatic segmentation of the choroidal layer could be also utilized in large-scale quantitative studies of the choroid.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336906PMC
http://dx.doi.org/10.4103/jmss.jmss_144_21DOI Listing

Publication Analysis

Top Keywords

automatic segmentation
16
oct images
12
optical coherence
8
coherence tomography
8
graph theory
8
manual segmentations
8
speckle noise
8
noise oct
8
curvelet transform-based
8
transform-based k-svd
8

Similar Publications

Posttraining Network Compression for 3D Medical Image Segmentation: Reducing Computational Efforts via Tucker Decomposition.

Radiol Artif Intell

January 2025

From the Department of Radiology, University Hospital, LMU Munich, Marchioninistr 15,81377 Munich, Germany (T.W., J.D., M.I.); Department of Statistics, LMU Munich, Munich, Germany (T.W., D.R.); and Munich Center for Machine Learning, Munich, Germany (T.W., J.D., D.R., M.I.).

Purpose To investigate whether the computational effort of 3D CT-based multiorgan segmentation with TotalSegmentator can be reduced via Tucker decomposition-based network compression. Materials and Methods In this retrospective study, Tucker decomposition was applied to the convolutional kernels of the TotalSegmentator model, an nnU-Net model trained on a comprehensive CT dataset for automatic segmentation of 117 anatomic structures. The proposed approach reduced the floating-point operations (FLOPs) and memory required during inference, offering an adjustable trade-off between computational efficiency and segmentation quality.

View Article and Find Full Text PDF

Purpose: Radiological follow-up of oncology patients requires the detection of metastatic lung lesions and the quantitative analysis of their changes in longitudinal imaging studies. Our aim was to evaluate SimU-Net, a novel deep learning method for the automatic analysis of metastatic lung lesions and their temporal changes in pairs of chest CT scans.

Materials And Methods: SimU-Net is a simultaneous multichannel 3D U-Net model trained on pairs of registered prior and current scans of a patient.

View Article and Find Full Text PDF

The hippocampus is a small, yet intricate seahorse-shaped tiny structure located deep within the brain's medial temporal lobe. It is a crucial component of the limbic system, which is responsible for regulating emotions, memory, and spatial navigation. This research focuses on automatic hippocampus segmentation from Magnetic Resonance (MR) images of a human head with high accuracy and fewer false positive and false negative rates.

View Article and Find Full Text PDF

Automated Classification of Cardiac Arrhythmia using Short-Duration ECG Signals and Machine Learning.

Biomed Phys Eng Express

January 2025

Electronics and Communication Engineering, Rajiv Gandhi University, Rono Hills, Doimukh, ITANAGAR, Itanagar, Arunachal Pradesh, 791112, INDIA.

Accurate detection of cardiac arrhythmias is crucial for preventing premature deaths. The current study employs a dual-stage Discrete Wavelet Transform (DWT) and a median filter to eliminate noise from ECG signals. Subsequently, ECG signals are segmented, and QRS regions are extracted for further preprocessing.

View Article and Find Full Text PDF

Artificial Intelligence (AI) based auto-segmentation has demonstrated numerous benefits to clinical radiotherapy workflows. However, the rapidly changing regulatory, research, and market environment presents challenges around selecting and evaluating the most suitable solution. To support the clinical adoption of AI auto-segmentation systems, Selection Criteria recommendations were developed to enable a holistic evaluation of vendors, considering not only raw performance but associated risks uniquely related to the clinical deployment of AI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!