A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing. | LitMetric

We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 10 were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346211PMC
http://dx.doi.org/10.3390/s23136177DOI Listing

Publication Analysis

Top Keywords

s-shaped double-spiral
12
evanescent field
12
refractive sensitivity
8
field sensing
8
cavity area
8
length dsr
8
dsr structures
8
quality factors
8
microring resonators
8
sensitivity
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!