In recent years, the use of inertial-based systems has been applied to remote rehabilitation, opening new perspectives for outpatient assessment. In this study, we assessed the accuracy and the concurrent validity of the angular measurements provided by an inertial-based device for rehabilitation with respect to the state-of-the-art system for motion tracking. Data were simultaneously collected with the two systems across a set of exercises for trunk and lower limbs, performed by 21 healthy participants. Additionally, the sensitivity of the inertial measurement unit ()-based system to its malpositioning was assessed. Root mean square error () was used to explore the differences in the outputs of the two systems in terms of range of motion (), and their agreement was assessed via Pearson's correlation coefficient (PCC) and Lin's concordance correlation coefficient (CCC). The results showed that the -based system was able to assess upper-body and lower-limb kinematics with a mean error in general lower than 5° and that its measurements were moderately biased by its mispositioning. Although the system does not seem to be suitable for analysis requiring a high level of detail, the findings of this study support the application of the device in rehabilitation programs in unsupervised settings, providing reliable data to remotely monitor the progress of the rehabilitation pathway and change in patient's motor function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346135PMC
http://dx.doi.org/10.3390/s23136156DOI Listing

Publication Analysis

Top Keywords

lower limbs
8
device rehabilitation
8
-based system
8
correlation coefficient
8
system
6
evaluation upper
4
upper body
4
body lower
4
limbs kinematics
4
kinematics -based
4

Similar Publications

Background And Aims: Neuro-ischemic ulcers (NIU) present a substantial clinical and economic burden on the healthcare systems. This study aims to evaluate their healing rate, associated healthcare resource utilization, and prognostic factors influencing healing.

Methods: Consecutive patients attended specialist clinics or admitted to wards in three tertiary hospitals for new or existing NIUs from November 2019 to November 2021 were eligible for this study.

View Article and Find Full Text PDF

Background And Aims: When dealing with severely calcified lesions in endovascular therapy (EVT) for lower extremity artery disease (LEAD), navigating through severely calcified chronic total occlusion (CTO) using hard-tip guidewires can be challenging. To address this issue, we employed a novel highly intensive penetration (HIP) technique. This technique involves modifying the tail of a 0.

View Article and Find Full Text PDF

Purpose We aimed to report an innovative single-site endoscopic surgery for soft tissue lesions performed at our center. Methods All patients who underwent soft tissue surgery were reviewed. All consecutive patients who underwent single-site endoscopic surgery between September 2019 and March 2024 were included in the study.

View Article and Find Full Text PDF

Objective: This study aims to investigate the sources of later response in epidural spinal recordings (ESRs) obtained from implanted leads during spinal cord stimulation, a topic has not been widely studied in previous research.

Methods: Two patients with lower back and lower extremity pain underwent SCS implantation with intraoperative neuromonitoring (IONM). The timing of extracted peaks in ESRs and intramuscular electromyography (EMG) recordings were analyzed and compared to a Monte Carlo simulation for synchronization analysis.

View Article and Find Full Text PDF

Background: Osoto-gari is a leg throw technique that primarily relies on the hip extension to initiate the sweeping motion of the leg. A high sweep contact velocity is a crucial factor in efficiently executing this technique. While some literature emphasises whole-body coordination in the leg-sweeping action, the roles of trunk and head motion remain unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!