Capacitive sensors that utilize the Coplanar Interdigitated (CID) electrode structure are widely employed in various technical and analytical domains, such as healthcare, infectious disease management, pharmaceuticals, metrology, and environmental monitoring. The present exigency for lab-on-a-chip contrivances and the requisite for the miniaturization of sensors have led to the widespread adoption of CID sensors featuring multiple dielectric layers (DLs), either in the form of substrates or superstrates. Previously, we derived an analytical model for the capacitance of CID capacitive sensors with four distinct 1-N-1 patterns (namely, 1-1-1, 1-3-1, 1-5-1, and 1-11-1) using partial capacitance (PC) and conformal mapping (CM) techniques. The aforementioned model has been employed in various applications wherein the permittivity of successive layers exhibits a monotonic decrease as one moves away from the electrode plane, resulting in highly satisfactory outcomes. Nevertheless, the PC technique is inadequate for structures with multiple layers where the permittivity exhibits a monotonic increase as the distance from the electrodes increases. Given these circumstances, it is necessary to adapt the initial PC method to incorporate these novel configurations. In this work, we have discussed a new approach, splitting the concept of PC into partial parallel capacitance (PPC) and partial serial capacitance (PSC), where new CM transformations are proposed for the latter case. Thus, the present study proposes a novel methodology to expand upon our prior analytical framework, which aims to incorporate scenarios where the permittivity experiences a reduction across successive layers. The outcomes are juxtaposed with the finite element simulation and analytical findings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346199 | PMC |
http://dx.doi.org/10.3390/s23135838 | DOI Listing |
ACS Meas Sci Au
December 2024
Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75248, United States.
This research aims to develop a portable biosensor device for quickly detecting vWFA2, a biomarker for inflammatory conditions. This sensor could dramatically change detection methods and lead us to improve the sensitivity of our tests to overcome the limitations of conventional detection methods. Our label-free biomolecular assay is constructed on an Au-ZnO electrode surface and uses electrochemical impedance spectroscopy (EIS) to measure the capacitive change in impedance, revealing the binding effects of the target vWFA2, to the capture probe.
View Article and Find Full Text PDFAdv Funct Mater
October 2024
Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
Flexible and stretchable strain sensors are in high demand in sports performance monitoring, structural health monitoring, and biomedical applications. However, existing stretchable soft sensors, primarily based on soft polymer materials, often suffer from drawbacks, including high hysteresis, low durability, and delayed response. To overcome these limitations, we introduced a stretchable miniature fiber sensor comprised of a stretchable core tightly coiled with parallel conductive wires.
View Article and Find Full Text PDFJ Diabetes Sci Technol
December 2024
Edward Hines, Jr. VA Hospital, Hines, IL, USA.
Background: Treatment of diabetes and its complications is a primary health care expense. Up to 25% of people with diabetes will develop diabetic foot ulcers (DFUs). Removable cast walker (RCW) boots commonly prescribed for DFU treatment, promote healing, and provide offloading and wound protection.
View Article and Find Full Text PDFBioinspir Biomim
December 2024
Biomimetics Laboratory, The University of Auckland Auckland Bioengineering Institute, 70 Symonds Street, Level 6, Auckland, 1010, NEW ZEALAND.
The propulsive fins of ray-finned fish are used for large scale locomotion and fine maneuvering, yet also provide sensory feedback regarding hydrodynamic loading and the surrounding environment. This information is gathered via nerve cells in the webbing between their fin rays. A similar bioinspired system that can gather force feedback from fin motion could enable valuable insight into robotic underwater locomotion improving swimming efficiency and orientation.
View Article and Find Full Text PDFSmall
December 2024
School of Materials Science &Engineering, Tongji University, Shanghai, 201804, P. R. China.
Hydrogel-based flexible electronic components have become the optimal solution to address the rigidity problem of traditional electronics in health management. In this study, a multipurpose hydrogel is introduced, which is formed by combining a dual-network consisting of physical (chitosan, polyvinyl alcohol (PVA)) and chemical (poly(isopropyl acrylamide (NIPAM)-co-acrylamide (AM))) cross-linking, along with signal conversion fillers (eutectic gallium indium (EGaIn), TiC MXene, polyaniline (PANI)) for responding to external stimuli. Multiple sensing of dynamic and static signals is permissible for it.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!