Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study aimed to assess the light transmittance (T) and temperature increase through different increments of dual-cure bioactive bulk-fill restorative material (ACTIVA), light-cure bulk-fill, and conventional composite resin materials. Cylindrical specimens with a diameter of 8 mm and heights of 1, 2, 3, and 4 mm of ACTIVA, Tetric-N-Ceram bulk-fill (TBF), Filtek One bulk-fill (FBF), and Filtek Z250 (FZ) (n = 6 per group, 96 in total) were light-cured with a visible blue low-intensity light-emitting diode (LED) (650-800 mW/cm irradiance). T, and the temperature increase, were measured using an optical power meter and a digital thermometer during curing. The T mean values ranged between 0.012 and 0.239 (76.02 to 98.81% light attenuation), while the temperature rise mean values ranged between 9.02 and 20.80 °C. The parameters, including material type (partial eta squared (ηp) = 0.284, < 0.0001), thickness (ηp = 0.284, < 0.0001), and their interaction (ηp = 0.185, = 0.047), significantly affected the T values, whereas only the material type (ηp = 0.352, = 0.047) affected the temperature rise values. The T and temperature rise mean values were highest in ACTIVA increments of 1-mm increments, in particular, showing the highest T mean values, followed by similar increments of TBF. A significantly higher T was found in 1-mm increments compared to thicker increments for all materials ( < 0.0001), and a significant positive correlation existed between T and temperature rise values ( = 0.348, = 0.001). These findings show that the bioactive material ACTIVA and TBF allow for better T than the other materials, with ACTIVA recording a higher temperature rise. However, the large light attenuation observed for all materials, irrespective of thickness, suggests that curing in more than one location with a low-intensity LED is necessary to optimize the curing process. Furthermore, incremental filling of bulk-fill materials using a low intensity LED could be beneficial.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10347211 | PMC |
http://dx.doi.org/10.3390/polym15132837 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!