Graphene oxide sheets fixed over silica particles (SiGO) and their modification functionalized with C18 and endcapped (SiGO-C18ec) have been reported as sorbents for extraction and analytical columns in LC. In this study, a SiGO column was selected as the extraction column and a SiGO-C18ec as the analytical column to study the applicability and limitations of a column-switching system composed exclusively of columns packed with graphene-based sorbents. Pyriproxyfen and abamectin B1a were selected as the analytes, and orange-flavored carbonated soft drinks as the matrix. The proposed system could be successfully applied to the pyriproxyfen analysis in a concentration range between 0.5 to 25 µg/mL presenting a linearity of R = 0.9931 and an intra-day and inter-day accuracy of 82.2-111.4% (RSD < 13.3%) and 95.5-99.8% (RSD < 12.7%), respectively. Furthermore, the matrix composition affected the area observed for the pyriproxyfen: the higher the concentration of orange juice in the soft drink, the higher the pyriproxyfen the signal observed. Additionally, the SiGO extraction column presented a life use of 120 injections for this matrix. In contrast, the proposed system could not apply to the analysis of abamectin B1a, and the SiGO-C18ec analytical column presented significant tailing compared to a similar approach with a C18 analytical column.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343772 | PMC |
http://dx.doi.org/10.3390/molecules28134999 | DOI Listing |
J Chromatogr Sci
December 2024
Analytical Research Laboratory, Cadila Pharmaceuticals Ltd., Dholka, Ahmedabad 382225, India.
N-nitrosamine impurities have been detected in a vast variety of drug substances and drug products, showing concern for regulatory aspects. To meet the regulatory requirement for the concerned impurity, a sensitive analytical method capable of quantifying these impurities at a lower level with accuracy and precision is required. This article focuses on the development and validation of an analytical method for the simultaneous detection of nine nitrosamine impurities in a single method for nebivolol drug product using liquid chromatography-mass spectrometry/mass spectrometry-atmospheric pressure chemical ionization (LC-MS/MS-APCI).
View Article and Find Full Text PDFFood Chem
December 2024
Department of Applied Chemistry ⋅ Food Science and Technology, Dong-eui University, Busan, Republic of Korea. Electronic address:
In this study, a robust and validated UHPLC-QqQ-MS/MS method was developed to quantify anserine and carnosine levels and their ratios to distinguish the geographical origin of red seabream (Pagrus major) from Japan and Korea. Comprehensive optimization of column types, mobile phase pH, organic solvent ratios, and internal standards identified the optimal conditions: an HILIC column at pH 5 with 75 % acetonitrile and PEH as the internal standard. The method exhibited excellent sensitivity, linearity, accuracy, and precision, establishing anserine as the most reliable biomarker for origin discrimination.
View Article and Find Full Text PDFSe Pu
January 2025
School of Public Health, Nanjing Medical University, Nanjing 211166, China.
Chlorinated coumarins, which are as cytotoxic as highly toxic halobenzoquinones toward CHO-K1 cells, have recently been identified as disinfection byproducts in drinking water disinfection processes. Therefore, detecting coumarins in water samples collected at various stages from drinking water treatment plants helps assess the formation of chlorinated coumarins in drinking water. Hence, a simple, rapid, accurate, and sensitive method for quantifying coumarins in water samples is required.
View Article and Find Full Text PDFSe Pu
January 2025
Research Center for Eco-Environmental Engineering, Dongguan University of Technology, Dongguan 523808, China.
Halogenated organic pollutants (HOPs) have attracted considerable attention owing to their persistence, bioaccumulation, and toxicity. The development of methods to detect HOPs in fish is challenging owing to the compositional complexity of fish matrices, which contain high levels of lipids and relatively low concentrations of HOPs. In addition, the lipophilicity of most HOPs renders their extraction difficult.
View Article and Find Full Text PDFJ Sep Sci
December 2024
Natural and Medical Sciences Research Center, University of Nizwa, Nizwa City, Oman.
Micellar liquid chromatography (MLC) has proven beneficial efficiency and ecological impact for routine quality control activities. In the proposed study, cyrene was investigated for the first time, together with other green additives, as a novel safe organic solvent in reversed-phase MLC. Quality-by-design (QbD) approach screened their effect on the separation performance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!