Dabigatran etexilate, an oral prodrug, is often used to treat complications linked to thrombosis. Dabigatran (DAB, active form) does not need to be monitored. However, there are several conditions, such as reduced renal function, traumatic bleeding, emergency surgery, the need for thrombolytic therapy in acute stroke, or the requirement to use other forms of anticoagulation, where knowing the concentration of DAB in the blood is indispensable. Unfortunately, there are no convenient DAB-specific point-of-care tests available. To solve this problem, two disposable sensors were constructed and optimised in this work to detect the anticoagulant drug DAB using novel co-facing disposable electrodes, which allows a calibration-free quantitation of the electroactive mediator concentration. A trypsin-based sensor was evaluated. This sensor performed well in a 10 mM Tris buffer (pH 8.8) solution. However, trypsin was inhibited by alpha-1 antitrypsin when a plasma sample was introduced into the sensor. This problem was overcome by plasma filtration. This sensor showed a detection limit of 50.7 ng mL DAB in plasma and a quantification range of 177-500 ng mL. A thrombin-based sensor was also constructed. This sensor performed well in ten-fold diluted plasma, overcoming the filtration problem observed with the trypsin-based sensor. This sensor showed a detection limit of 9.6 ng mL DAB in plasma and a quantification range of 11.5-140 ng mL. Its extensive pH stability range, the possibility of working at physiological pH, low volume, low cost, and fast turnaround response (less than 20 s) make the calibration-free thrombin-based sensor a suitable point-of-care test to measure DAB concentration in the blood.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343278PMC
http://dx.doi.org/10.3390/molecules28134953DOI Listing

Publication Analysis

Top Keywords

sensor
9
trypsin-based sensor
8
sensor performed
8
performed well
8
sensor detection
8
detection limit
8
dab plasma
8
plasma quantification
8
quantification range
8
thrombin-based sensor
8

Similar Publications

Including sensor information in medical interventions aims to support surgeons to decide on subsequent action steps by characterizing tissue intraoperatively. With bladder cancer, an important issue is tumor recurrence because of failure to remove the entire tumor. Impedance measurements can help to classify bladder tissue and give the surgeons an indication on how much tissue to remove.

View Article and Find Full Text PDF

This study aims to evaluate the efficiency and energy release characteristics of different types of coal in pulse detonation engines (PDE) to advance the development of deep coal fluidization detonation technology, achieving more efficient and cleaner coal utilization. Using a custom PDE setup, experiments were conducted with four coal types at mass flow rates from 30 to 120 g/s. High-frequency pressure sensors assessed pressure dynamics and detonation wave propagation, complemented by numerical simulations for accuracy.

View Article and Find Full Text PDF

On-site biosignal amplification using a single high-spin conjugated polymer.

Nat Commun

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, School of Materials Science and Engineering, Peking University, Beijing, China.

On-site or in-sensor biosignal transduction and amplification can offer several benefits such as improved signal quality, reduced redundant data transmission, and enhanced system integration. Ambipolar organic electrochemical transistors (OECTs) are promising for this purpose due to their high transconductance, low operating voltage, biocompatibility, and suitability for miniaturized amplifier design. However, limitations in material performance and stability have hindered their application in biosignal amplification.

View Article and Find Full Text PDF

In terms of safety and emergency response, identifying hazardous gaseous acid chemicals is crucial for ensuring effective evacuation and administering proper first aid. However, current studies struggle to distinguish between different acid vapors and remain in the early stages of development. In this study, we propose an on-site monitorable acid vapor decoder, MOF-808-EDTA-Cu, integrating the robust MOF-808 with Cu-EDTA, functioning as a proton-triggered colorimetric decoder that translates the anionic components of corrosive acids into visible colors.

View Article and Find Full Text PDF

The paper presents a new sensor-less voltage and frequency control method for a stand-alone doubly-fed induction generator (DFIG) feeding an isolated load. The proposed control approach directly regulates the magnitude and angle of the rotor-flux vector rather than controlling rotor currents or voltages as in classic field oriented control (FOC). To accurately regulate the magnitude and frequency of stator voltage, two separate closed-loop based PI regulators are employed to evaluate the reference signals of the rotor flux vector magnitude and angle, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!