Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
(1) Although the accuracy of static computer-aided implant surgery (sCAIP) is well reported, information on its long-term effect on peri-implant health and complications is scarce. (2) Twenty-six patients initially treated were recalled. Implant survival, radiographic bone level, peri-implant health, and complications were registered. A multilevel regression model was applied to study the relationship between the research variables. (3) Sixteen patients participated in this study (average age 58.5 years; range 27.8-73.8). The mean follow-up time was 9.1 years (range 7.3-11.3). Two implants failed, resulting in a survival rate of 97.1%. The mean bone level change corresponded to a loss of 0.63 mm (SD 1.90) for the whole group, 0.17 mm (SD 1.46), and 0.91 mm (SD 2.09) for tooth- and mucosa-supported guides, respectively. The mean PPD for the total group was 4.24 mm (SD 1.25), and 3.79 mm (SD 0.97) and 4.51 mm (SD 1.33) for the tooth- and mucosa-supported guides, respectively. Four implants (6.3%) were diagnosed with peri-implantitis. Coronal deviation was slightly associated with having a negative impact on bone level at follow-up, but this was not statistically significant. Seven patients (43.8%) experienced technical complications. Biological complications were seen in 3/16 patients (18.75%). (4) SCAIP may contribute to more predictable implant placement; the long-term clinical outcome is similar to conventional nonguided surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342361 | PMC |
http://dx.doi.org/10.3390/jcm12134432 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!