A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preclinical trial of the effectiveness of a safety nasogastric tube to detect the tube position based on tidal volume and pepsin assay results in the gastrointestinal tract of Macaca fascicularis. | LitMetric

Background: Tube misplacement into the tracheobronchial tract is associated with pneumothorax in 0.5% of cases. NGT verification only detects the position of the tube at the end of the procedure. Therefore, a safe nasogastric tube (SNGT) was created to detect the NGT position in real time in a simple and inexpensive way. This study aimed to prove the effectiveness of the SNGT prototype in Macaca fascicularis.

Result: An SNGT producing 50% of the TV had 100% sensitivity and specificity in detecting the position of the tube at 100% of the TV, with a sensitivity of 100% and a specificity of 87.5%. There was a significant difference between the movement of the SNGT 50% TV and SNGT 100% TV airbags (p ≤ 0.05). However, there was no significant difference between the accuracy of placement of the 50% TV SNGT, 100% TV SNGT, and conventional NGT (p > 0.05). The pepsin enzyme had better sensitivity (100%) than pH paper (91.66%) in detecting the end-of-procedure tube position. This research has the potential to advance into human clinical trials.

Conclusion: SNGTs are highly effective in detecting the NGT position inside the respiratory and digestive tracts to prevent misplacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339581PMC
http://dx.doi.org/10.1186/s12938-023-01128-5DOI Listing

Publication Analysis

Top Keywords

nasogastric tube
8
tube position
8
position tube
8
ngt position
8
100% sensitivity
8
sensitivity 100%
8
50% sngt
8
sngt 100%
8
tube
7
sngt
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!