Background: Broad implementation of the American Board of Surgery's entrustable professional activities initiative will require assessment instruments that are reliable and easy to use. Existing assessment instruments of general laparoscopic surgical skills have limited reliability, efficiency, and validity across the spectrum of formative (low-stakes) and summative (high-stakes) assessments. A novel six-item global assessment of surgical skills (GASS) instrument was developed and evaluated with a focus upon safe versus unsafe surgical practice scoring rubric.
Methods: The GASS was developed by iterative engagement with expert laparoscopic surgeons and includes six items (economy of motion, tissue handling, appreciating operative anatomy, bimanual dexterity, achievement of hemostasis, overall performance) with a uniform three-point scoring rubric ("poor-unsafe", "adequate-safe", "good-safe"). To test inter-rater reliability, a cross-sectional study of four bariatric surgeons with experience ranging from 4 to 28 years applied the GASS and the global operative assessment of laparoscopic skills (GOALS) to 30 consecutive Roux-en-Y gastric bypass procedure operative videos. Inter-rater reliability was assessed for a simplified dichotomous "safe" versus "unsafe" scoring rubric using Gwet's AC.
Results: The GASS inter-rater reliability was very high across all six domains (0.88-1.00). The GASS performed comparably to the GOALS inter-rater reliability scores (0.96-1.00). The economy of motion and bimanual dexterity items had the highest percentage of unsafe ratings (9.2% and 5.8%, respectively).
Conclusion: The GASS, a novel six-item instrument of general laparoscopic surgical skills, was designed with a simple scoring rubric (poor-safe, adequate-safe, good-safe) to minimize rater burden and focus feedback to trainees and promotion evaluations on safe surgical performance. Initial evaluation of the GASS is promising, demonstrating high inter-rater reliability. Future research will seek to assess the GASS against a broader spectrum of laparoscopic procedures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-023-10116-8 | DOI Listing |
Sci Rep
January 2025
Department of Infectious Diseases and Clinical Microbiology, Bakirkoy Dr Sadi Konuk Training and Research Hospital, Istanbul, 34140, Turkey.
This is the first study to evaluate the adequacy and reliability of the ChatGPT and Gemini chatbots on viral hepatitis. A total of 176 questions were composed from three different categories. The first group includes "questions and answers (Q&As) for the public" determined by the Centers for Disease Control and Prevention (CDC).
View Article and Find Full Text PDFBr J Nurs
January 2025
Physiotherapist, AZ Alma Eeklo, Belgium.
In health care, work-related musculoskeletal disorders are largely attributed to patient-handling tasks. Reliable assessments of patient mobility are imperative to mitigate the musculoskeletal burden on healthcare providers. This study explores the reliability of MK5 Mobility Classes, a patient mobility classification system.
View Article and Find Full Text PDFJ Esthet Restor Dent
January 2025
Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Objective: To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.
Material And Methods: Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.
J Neural Eng
January 2025
Department of Physical Medicine and Rehabilitation, MetroHealth Medical Center, 4229 Pearl Road, Suite N4-13, Cleveland, Ohio, 44109-1998, UNITED STATES.
Ipsilateral motor evoked potentials (iMEPs) are believed to represent cortically evoked excitability of uncrossed brainstem-mediated pathways. In the event of extensive injury to (crossed) corticospinal pathways, which can occur following a stroke, uncrossed ipsilateral pathways may serve as an alternate resource to support the recovery of the paretic limb. However, iMEPs, even in neurally intact people, can be small, infrequent, and noisy, so discerning them in stroke survivors is very challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!