Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Dental radiology represents the best model for evaluating the effects of low-dose ionizing radiation. Therefore, this study evaluated the awareness on radiation hygiene among dental ancillary personnel through a questionnaire and their absorbed doses by physical and biologic dosimetry.
Methods: The multicentric study included two groups. Group I (N = 30) consisted of dental staff involved in dental radiology. An equal number of personnel who were not related to radiology formed the control group. Knowledge (K), attitude (A), and practice (P) of participants were assessed using a KAP questionnaire. Radiation exposure was evaluated by physical dosimetry at 3 time periods: at the beginning of the study (T1), after 10 months (T2), and at the end after 20 months (T3). Similarly, biologic dosimetry was also carried out at 3 time points by dicentric chromosome aberration assay. The data were compared using percentage analysis, analysis of variance (one-way analysis of variance), and Student's t- test.
Results: The KAP survey demonstrated enhanced understanding of radiation protection measures and its sound practice by the participants. Physical dosimetry showed a significant increase in absorbed dose at 3 time points: T1, T2, and T3. However, no chromosomal aberrations were observed in blood lymphocytes for any of the participants in the optimized 4-day biodosimetry protocol.
Conclusion: Good radiation protection protocols-safe distance from the radiation source and wear of lead aprons and thyroid collars-ensured low absorbed doses. The 4-day protocol is an important step toward developing biodosimetry laboratories in the Armed Forces Medical Services for clinical and national radiation countermeasure strategies.