A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicentric evaluation of conventional dosimetry vs bio-dosimetry over a period of two years for a three-point contact. | LitMetric

Background: Dental radiology represents the best model for evaluating the effects of low-dose ionizing radiation. Therefore, this study evaluated the awareness on radiation hygiene among dental ancillary personnel through a questionnaire and their absorbed doses by physical and biologic dosimetry.

Methods: The multicentric study included two groups. Group I (N = 30) consisted of dental staff involved in dental radiology. An equal number of personnel who were not related to radiology formed the control group. Knowledge (K), attitude (A), and practice (P) of participants were assessed using a KAP questionnaire. Radiation exposure was evaluated by physical dosimetry at 3 time periods: at the beginning of the study (T1), after 10 months (T2), and at the end after 20 months (T3). Similarly, biologic dosimetry was also carried out at 3 time points by dicentric chromosome aberration assay. The data were compared using percentage analysis, analysis of variance (one-way analysis of variance), and Student's t- test.

Results: The KAP survey demonstrated enhanced understanding of radiation protection measures and its sound practice by the participants. Physical dosimetry showed a significant increase in absorbed dose at 3 time points: T1, T2, and T3. However, no chromosomal aberrations were observed in blood lymphocytes for any of the participants in the optimized 4-day biodosimetry protocol.

Conclusion: Good radiation protection protocols-safe distance from the radiation source and wear of lead aprons and thyroid collars-ensured low absorbed doses. The 4-day protocol is an important step toward developing biodosimetry laboratories in the Armed Forces Medical Services for clinical and national radiation countermeasure strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10334216PMC
http://dx.doi.org/10.1016/j.mjafi.2021.03.008DOI Listing

Publication Analysis

Top Keywords

dental radiology
8
absorbed doses
8
practice participants
8
physical dosimetry
8
time points
8
analysis variance
8
radiation protection
8
radiation
7
multicentric evaluation
4
evaluation conventional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!