Initial retention force of three attachment systems for implant retained-mandibular overdentures: An in vitro study.

J Prosthodont

Laboratory URP2496 Orofacial Pathologies, Imaging and Biotherapies, Faculty of odontology, Université Paris Cité, Montrouge, France.

Published: June 2024

Purpose: To evaluate and compare the initial retention force of three resilient unsplinted attachment systems for implant-retained mandibular overdentures: two cylindrical attachment systems (Locator R-Tx® and Novaloc®), and one ball attachment system (Ball System).

Materials And Methods: For each attachment system, initial retention is measured as the average of the maximal dislodging forces during 10 insertion-removal cycles. For the Ball System, three activation degrees of the matrix are included versus four and six color-coded retention devices for the Locator R-Tx® and the Novaloc®, respectively, to represent the complete regular retention devices panel. For each retention device or activation degree, eight samples are tested.

Results: The initial retention range is similar between the Ball System (7.7 ± 3.4 N - 19.9 ± 4.6 N) and the Novaloc® (2.0 ± 0.5 N - 18.9 ± 1.4 N) and broader for the Locator R-Tx® (3.3 ± 5.0 N - 60.2 ± 6.0 N). In each attachment system, the initial retention of each retention device is significantly different from the others, except for the two most retentive Novaloc® ones. Retention devices were also classified according to their initial retention (low, medium, and maximum). In each retention group, the Novaloc® and the Ball System provided similar retention values lower than the Locator R-Tx®.

Conclusion: Most of the retention devices tested provided an initial retention force of over 5 N for all three attachment systems. The Locator R-Tx® had the most comprehensive range, and the Novaloc® seemed to provide the most reproducible values, unlike the Ball System due to the activation required by the operator.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13729DOI Listing

Publication Analysis

Top Keywords

initial retention
28
attachment systems
16
locator r-tx®
16
ball system
16
retention devices
16
retention
14
retention force
12
force three
12
attachment system
12
three attachment
8

Similar Publications

Mismatched electron and proton transport rates impede the manifestation of effective performance of the electrocatalytic oxygen evolution reaction (OER), thereby limiting its industrial applications. Inspired by the natural protein cluster in PS-II, different organic-inorganic hybrid electrocatalysts were synthesized via a hydrothermal method. -Toluidine (PT), benzoic acid (BA), and -aminobenzoic acid (PABA) were successfully intercalated into NiFe-LDH.

View Article and Find Full Text PDF

Objectives: This pilot study aimed to identify early predictors of drug retention in patients with clinically active peripheral psoriatic arthritis who initiated or switched to therapy with biologic and targeted synthetic disease-modifying antirheumatic drugs (bDMARDs and tsDMARDs).

Methods: Clinical and ultrasound assessments were conducted at baseline (t0) and subsequently at 1 (t1), 3 (t3), and 6 (t6) months. Ultrasound evaluations targeted joints/entheses according to PsASon-Score13 and the most clinically involved joint/enthesis/tendon or the two most clinically involved joints/entheses/tendons (MIJET and 2MIJET).

View Article and Find Full Text PDF

Background: We previously published a systematic review evaluating retention in care after antiretroviral therapy treatment initiation among adults in low- and middle-income countries. We estimated retention at 36 months to be at 74% for studies published from 2008-2013. This review evaluates retention after the implementation of Universal Test and Treat in 2015.

View Article and Find Full Text PDF

Using High-Entropy Configuration Strategy to Design Spinel Lithium Manganate Cathodes with Remarkable Electrochemical Performance.

Small

January 2025

National and Local Joint Engineering Laboratory for Lithium-ion Batteries and Materials Preparation Technology, Key Laboratory of Advanced Battery Materials of Yunnan Province, Faculty of Metallurgical and Energy Engineering, Faculty of Materials Science and Engineering, Kunming University of Science and Technology, Kunming, 650093, China.

Owing to its abundant manganese source, high operating voltage, and good ionic diffusivity attributed to its 3D Li-ion diffusion channels. Spinel LiMnO is considered a promising low-cost positive electrode material in the context of reducing scarce elements such as cobalt and nickel from advanced lithium-ion batteries. However, the rapid capacity degradation and inadequate rate capabilities induced by the Jahn-Teller distortion and the manganese dissolution have limited the large-scale adoption of spinel LiMnO for decades.

View Article and Find Full Text PDF

Introduction: Surgical site infection (SSI) is one of the most serious postoperative complications following instrumented spinal surgery. We previously reported the potential of continuous local antibiotic perfusion (CLAP) to retain implants for patients with SSI following instrumented spinal surgery. We conducted a retrospective multicenter study to elucidate the efficacy and limitations of CLAP for patients with SSI following instrumented spinal surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!