Four indices on Gd-EOB-DTPA-enhanced MRI can estimate liver functional reserve compared to ICG-R15: A systematic review and meta-analysis.

Clin Imaging

Department of Gastroenterology, The First Affiliated Hospital of Xinjiang Medical University, No. 137, Liyushan Road, Xinshi District, Urumqi, Xinjiang Uygur Autonomous Region 830000, China; Department of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, 324, Jing 5 Rd, Jinan, Shandong Province 250021, China. Electronic address:

Published: October 2023

Aims: To evaluate the value of four indices of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced (Gd-EOB-DTPA) magnetic resonance as a potential imaging marker of liver functional reserve.

Methods: PubMed/Medline, Embase, Cochrane Library, and Web of Science were searched for studies concerning the relationship between Gd-EOB-DTPA-enhanced MRI and liver functional reserve estimated by ICG-R15, Pooled correlation coefficient (r) and 95% confidence intervals (CIs) were calculated, Meanwhile, Sensitivity and subgroup analyses were performed along with Egger's test for the estimation of publication bias and potential heterogeneity.

Results: 14 publications with 1285 patients were included. The pooled r between relative liver enhancement (RLE), reduction rate of T1 relaxation time of the liver (rrT1), liver-to-spleen ratio (LSR), liver-to-muscle ratio (LMR), and ICG-R15 were -0.49 (95% CI, -0.56 to -0.41, p < 0.05), -0.47 (95% CI, -0.57 to -0.36, p < 0.05), -0.45 (95% CI, -0.55 to -0.34, p < 0.05), -0.50 (95% CI, -0.61 to -0.38, p < 0.05). moderate heterogeneity was observed between studies on rrT1, LSR, LMR, and ICG-R15 (p ≤ 0.05), but no significant heterogeneity was observed between RLE and ICG-R15. Further analysis shows that there was a notable heterogeneity between subgroup analysis of LSR and ICG-R15 stratified by years of publication, as well as rrT1 and LMR stratified by total patients and study design, the distribution funnel plots and the results of Egger's test showed no evidence of publication bias.

Conclusions: RLE, LSR, LMR, and rrT1 all correlated significantly with ICG-R15-estimated hepatic functional reserve. The four indices represent a promising imaging biomarker in the prediction of liver functional reserve.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinimag.2023.06.018DOI Listing

Publication Analysis

Top Keywords

liver functional
12
gd-eob-dtpa-enhanced mri
8
functional reserve
8
liver
5
indices gd-eob-dtpa-enhanced
4
mri estimate
4
estimate liver
4
reserve compared
4
compared icg-r15
4
icg-r15 systematic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!