Point-of-care testing methods currently utilize rapid, portable, inexpensive, and multiplexed on-site detection. Microfluidic chips have become a very promising platform with broad development prospects due to their breakthrough improvement in miniaturization and integration. However, the conventional microfluidic chips still have disadvantages, such as difficulty in fabrication processing, long production time and high cost, which hinder its applications in the fields of POCT and in vitro diagnostics. In this study, a capillary-based microfluidic chip with the characteristics of low cost and easy fabrication was developed for the rapid detection of acute myocardial infarction (AMI). Several short capillaries, which were already conjugated with the capture antibodies respectively, were connected by peristaltic pump tubes and then formed the working capillary. Two working capillaries were encapsulated in the plastic shell and ready for the immunoassay. Multiplex detection of Myoglobin (Myo), cardiac troponin I (cTnI) and creatine kinase-MB (CK-MB) were chosen to demonstrate the feasibility and analytical performance of the microfluidic chip, which requires rapid and accurate detection during diagnosis and therapy for AMI. The capillary-based microfluidic chip required tens of minutes to prepared, and its cost was less than $1. The limit of detection (LOD) was 0.5 ng/mL for Myo, 0.1 ng/mL for cTnI and 0.5 ng/mL for CK-MB respectively. The capillary-based microfluidic chips with easy fabrication and low cost hold promise for the portable and low-cost detection of target biomarkers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2023.124924 | DOI Listing |
J Chem Phys
November 2024
Joint Laboratory of Optofluidic Technology and Systems, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics, South China Normal University, Guangzhou 510006, China.
Cryst Growth Des
October 2024
Department of Chemical and Biomolecular Engineering, NYU Tandon School of Engineering, Brooklyn, New York 11201, United States.
A capillary-based microfluidic system designed for nonphotochemical laser-induced nucleation (NPLIN) studies coupled with real-time microscopy was used to study NPLIN of iron (II,III) oxide doped aqueous KCl solutions. Supersaturation was achieved by lowering the solution temperature using thermoelectric cooling, and heating was used for the dissolution of crystals downstream to prevent clogging during the flow. The effect of nanoparticle concentration, supersaturation, laser intensity, and filtration was studied.
View Article and Find Full Text PDFAnal Chim Acta
August 2024
Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China. Electronic address:
Sci Rep
May 2024
Center for Biomedical Engineering, School of Engineering, Brown University, Providence, RI, USA.
Next-generation sequencing (NGS) is emerging as a powerful tool for molecular diagnostics but remains limited by cumbersome and inefficient sample preparation. We present an innovative automated NGS library preparation system with a simplified mechanical design that exploits both macro- and microfluidic properties for optimizing heat transfer, reaction kinetics, mass transfer, fluid mechanics, adsorption-desorption rates, and molecular thermodynamics. Our approach introduces a unique two-cannula cylindrical capillary system connected to a programmable syringe pump and a Peltier heating element able to execute all steps with high efficiency.
View Article and Find Full Text PDFACS Appl Bio Mater
December 2024
Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States.
Stereolithography (SLA) 3D printing is a rapid prototyping technique and reproducible manufacturing platform, which makes it a useful tool to develop advanced microfluidic devices for bioanalytical applications. However, limited information exists regarding the physical, chemical, and biological properties of the photocured polymers printed with SLA. This study demonstrates the characterization of a commercially available SLA 3D printed polymer to evaluate the potential presence of any time-dependent changes in material properties that may affect its ability to produce functional, capillary-action microfluidic devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!