A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of magnet strength on fetal brain biometry - a single-center retrospective MRI-based cohort study. | LitMetric

Effect of magnet strength on fetal brain biometry - a single-center retrospective MRI-based cohort study.

Neuroradiology

Section of Neuroradiology, Division of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, 2 Sheba Rd, 52621, Ramat Gan, Israel.

Published: October 2023

Purpose: Abnormal fetal brain measurements might affect clinical management and parental counseling. The effect of between-field-strength differences was not evaluated in quantitative fetal brain imaging until now. Our study aimed to compare fetal brain biometry measurements in 3.0 T with 1.5 T scanners.

Methods: A retrospective cohort of 1150 low-risk fetuses scanned between 2012 and 2021, with apparently normal brain anatomy, were retrospectively evaluated for biometric measurements. The cohort included 1.5 T (442 fetuses) and 3.0 T scans (708 fetuses) of populations with comparable characteristics in the same tertiary medical center. Manually measured biometry included bi-parietal, fronto-occipital and trans-cerebellar diameters, length of the corpus-callosum, vermis height, and width. Measurements were then converted to centiles based on previously reported biometric reference charts. The 1.5 T centiles were compared with the 3.0 T centiles.

Results: No significant differences between centiles of bi-parietal diameter, trans-cerebellar diameter, or length of the corpus callosum between 1.5 T and 3.0 T scanners were found. Small absolute differences were found in the vermis height, with higher centiles in the 3.0 T, compared to the 1.5 T scanner (54.6th-centile, vs. 39.0th-centile, p < 0.001); less significant differences were found in vermis width centiles (46.9th-centile vs. 37.5th-centile, p = 0.03). Fronto-occipital diameter was higher in 1.5 T than in the 3.0 T scanner (66.0th-centile vs. 61.8th-centile, p = 0.02).

Conclusions: The increasing use of 3.0 T MRI for fetal imaging poses a potential bias when using 1.5 T-based charts. We elucidate those biometric measurements are comparable, with relatively small between-field-strength differences, when using manual biometric measurements. Small inter-magnet differences can be related to higher spatial resolution with 3 T scanners and may be substantial when evaluating small brain structures, such as the vermis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-023-03193-yDOI Listing

Publication Analysis

Top Keywords

fetal brain
16
brain biometry
8
vermis height
8
brain
5
30 t
5
15 t
5
magnet strength
4
fetal
4
strength fetal
4
biometry single-center
4