AI Article Synopsis

  • Real-time sweat monitoring is crucial for athletes to assess their physical condition, exercise loads, and training effectiveness.
  • A developed multi-modal sweat sensing system includes a wireless sensor patch that measures key substances (lactate, glucose, K, Na) in sweat, with data relayed using NFC and BLE technology to a host controller.
  • To enhance sensor sensitivity, a dual enzyme sensing strategy using Laser-Induced Graphene and Single-Walled Carbon Nanotubes was proposed, resulting in effective and cost-efficient sensors suitable for mass production and capable of accurately monitoring personal fitness levels.

Article Abstract

Real-time sweat monitoring is vital for athletes in order to reflect their physical conditions, quantify their exercise loads, and evaluate their training results. Therefore, a multi-modal sweat sensing system with a patch-relay-host topology was developed, which consisted of a wireless sensor patch, a wireless data relay, and a host controller. The wireless sensor patch can monitor the lactate, glucose, K, and Na concentrations in real-time. The data is forwarded via a wireless data relay through Near Field Communication (NFC) and Bluetooth Low Energy (BLE) technology and it is finally available on the host controller. Meanwhile, existing enzyme sensors in sweat-based wearable sports monitoring systems have limited sensitivities. To improve their sensitivities, this paper proposes a dual enzyme sensing optimization strategy and demonstrates Laser-Induced Graphene (LIG)-based sweat sensors decorated with Single-Walled Carbon Nanotubes (SWCNT). Manufacturing an entire LIG array takes less than one minute and costs about 0.11 yuan in materials, making it suitable for mass production. The in vitro test result showed sensitivities of 0.53 μA/mM and 3.9 μA/mM for lactate and glucose sensing, and 32.5 mV/decade and 33.2 mV/decade for K and Na sensing, respectively. To demonstrate the ability to characterize personal physical fitness, an ex vivo sweat analysis test was also performed. Overall, the high-sensitivity lactate enzyme sensor based on SWCNT/LIG can meet the requirements of sweat-based wearable sports monitoring systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221498PMC
http://dx.doi.org/10.3390/s23104818DOI Listing

Publication Analysis

Top Keywords

sweat sensing
8
sensing system
8
wireless sensor
8
sensor patch
8
wireless data
8
data relay
8
host controller
8
lactate glucose
8
sweat-based wearable
8
wearable sports
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!