Investigation and Improvement of Test Methods for Capacitance and DCESR of EDLC Cells.

Sensors (Basel)

School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China.

Published: May 2023

AI Article Synopsis

  • * This study compared capacitance and DCESR of three commercial EDLC cells using IEC 62391, Maxwell, and QC/T741-2014 standards, highlighting significant differences in testing methods and their respective drawbacks.
  • * An improved testing method utilizing short-time constant voltage charging and discharging interruptions was proposed, offering higher accuracy, simpler requirements, and quicker results compared to the three standards.

Article Abstract

The quick and accurate characterization of commercial electrochemical double-layer capacitor (EDLC) cells, especially their capacitance and direct-current equivalent series internal resistance (DCESR), is of great significance for the design, maintenance, and monitoring of EDLCs used in areas of energy, sensors, electric power, construction machinery, rail transit, automobile transportation, and military. In this study, the capacitance and DCESR of three commercial EDLC cells with similar performance were determined and compared by following the three commonly-used standards of IEC 62391, Maxwell, and QC/T741-2014, which are significantly different in test procedures and calculation methods. The analysis of the test procedures and results demonstrated that the IEC 62391 standard has the disadvantages of a large testing current, long testing time, and a complex and inaccurate DCESR calculation, whereas the Maxwell standard has the disadvantages of a large testing current, a small capacitance, and large DCESR testing results, and furthermore the QC/T 741 standard has the disadvantages of a high resolution requirement for the equipment and small DCESR results. Therefore, an improved method was proposed to determine the capacitance and DCESR of EDLC cells by short-time constant voltage charging and discharging interruption methods, respectively, with the advantages of high accuracy, low equipment requirements, short testing time, and the easy calculation of DCESR over the original three standards.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223634PMC
http://dx.doi.org/10.3390/s23104717DOI Listing

Publication Analysis

Top Keywords

edlc cells
16
capacitance dcesr
12
standard disadvantages
12
dcesr
8
dcesr edlc
8
iec 62391
8
test procedures
8
disadvantages large
8
large testing
8
testing current
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!