Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A highly sensitive LC-MS/MS methods were developed and validated to quantify nine antiretrovirals (atazanavir [ATV], tenofovir [TFV], emtricitabine [FTC], darunavir [DRV], dolutegravir [DTG], efavirenz [EFV], lamivudine [3TC], raltegravir [RAL], and ritonavir [RTV]) in human cerebral spinal fluid (CSF). The approach remedies adsorption issues caused by polypropylene based sample collection tubes. 1% ammonium hydroxide in methanol was added in an amount equal to the volume of each quality control (QC) or patient sample. Protein precipitation was utilized with a CSF sample volume of 100 μL and a 100 μL of methanol:ACN and vortexed. Chromatographic separation was achieved with a 3 × 100 ACE® C18 column for ATV, DRV, DTG, EFV, RTV and RAL, and a 2 × 100 Polar RP column for TFV/FTC/3TC. Mobile phase was methanol:water:formic acid (70:30:0.1, v/v/v) for ATV, DRV, DTG, EFV and RTV (10 uL injection, flow rate: 1.00 mL/min), ACN:water:formic acid (35:65:0.1, v/v/v) for RAL (50 uL injection, flow rate: 1.00 mL/min), ACN:water:formic acid (2:98:0.1, v/v/v) for TFV, FTC and 3TC (50 uL injection, flow rate: 0.35 mL/min). Column temperature was 40° C across all assays. The mass spectrometer was operated in positive, multiple-reaction-monitoring (MRM) mode with electrospray ionization (ESI) for all analytes with the exception of EFV, which was operated in negative, MRM mode with ESI. The assay was linear over the calibration range of 1 to 250 ng/mL for all analytes. The addition of 1% ammonium hydroxide in sample tubes overcame up to 44% negative bias in QC samples and allowed the methods to meet full validation criteria.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10529871 | PMC |
http://dx.doi.org/10.1016/j.jchromb.2023.123810 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!