Background: Intraoperative neuromonitoring is widely used in thyroid and parathyroid surgery to prevent unilateral and especially bilateral recurrent nerve paresis. Reference values for amplitude and latency for the recurrent laryngeal nerve and vagus nerve have been published. However, data quality measures that exclude errors of the underlying intraoperative neuromonitoring (IONM) data (immanent software errors, false data labelling) before statistical analysis have not yet been implemented.
Methods: The authors developed an easy-to-use application (the Mainz IONM Quality Assurance and Analysis tool) using the programming language R. This tool allows visualization, automated and manual correction, and statistical analysis of complete raw data sets (electromyogram signals of all stimulations) from intermittent and continuous neuromonitoring in thyroid and parathyroid surgery. The Mainz IONM Quality Assurance and Analysis tool was used to evaluate IONM data generated and exported from 'C2' and 'C2 Xplore' neuromonitoring devices (inomed Medizintechnik GmbH) after surgery. For the first time, reference values for latency and amplitude were calculated based on 'cleaned' IONM data.
Results: Intraoperative neuromonitoring data files of 1935 patients consecutively operated on from June 2014 to May 2020 were included. Of 1921 readable files, 34 were excluded for missing data labelling. Automated plausibility checks revealed: less than 3 per cent device errors for electromyogram signal detection; 1138 files (approximately 60 per cent) contained potential labelling errors or inconsistencies necessitating manual review; and 915 files (48.5 per cent) were indeed erroneous. Mean(s.d.) reference onset latencies for the left vagus nerve, right vagus nerve, recurrent laryngeal nerve, and external branch of the superior laryngeal nerve were 6.8(1.1), 4.2(0.8), 2.5(1.1), and 2.1(0.5) ms, respectively.
Conclusion: Due to high error frequencies, IONM data should undergo in-depth review and multi-step cleaning processes before analysis to standardize scientific reporting. Device software calculates latencies differently; therefore reference values are device-specific (latency) and/or set-up-specific (amplitude). Novel C2-specific reference values for latency and amplitude deviate considerably from published values.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10332395 | PMC |
http://dx.doi.org/10.1093/bjsopen/zrad051 | DOI Listing |
Cureus
November 2024
Physiology, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.
Background Human growth and development involve significant changes in bodily dimensions, yet motor learning appears to remain stable throughout life. This study investigates whether adjustments in motor velocity take place as individuals age by examining the latency of transcranial motor-evoked potentials (TcMEPs) across different age groups. Methods Data were collected from 100 patients who underwent surgery with intraoperative neuromonitoring at the All India Institute of Medical Sciences, New Delhi, between January 1, 2019, and January 1, 2020.
View Article and Find Full Text PDFSurg Today
December 2024
Department of Surgery, Seoul National University College of Medicine, Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul, Korea.
NeuroSci
December 2024
Department of Palliative Medicine, Poznan University of Medical Sciences, 61-701 Poznań, Poland.
Background: Intraoperative neuromonitoring (IONM) is crucial for the safety of scoliosis surgery, providing real-time feedback on the spinal cord and nerve function, primarily through motor-evoked potentials (MEPs). The choice of anesthesia plays a crucial role in influencing the quality and reliability of these neuromonitoring signals. This systematic review evaluates how different anesthetic techniques-total intravenous anesthesia (TIVA), volatile anesthetics, and regional anesthesia approaches such as Erector Spinae Plane Block (ESPB), spinal, and epidural anesthesia-affect IONM during scoliosis surgery.
View Article and Find Full Text PDFWorld J Gastroenterol
December 2024
Department of Surgery and Centre of Minimal Invasive Surgery, GFO Kliniken Bonn, Bonn 53225, North Rhine-Westphalia, Germany.
This manuscript focused on the surgical challenge of urinary and sexual dysfunction after rectal cancer surgery based on the interesting results demonstrated by the observational study of Chen , which was published in the . Urinary dysfunction occurs in one-third of patients treated for rectal cancer. Surgical nerve damage is the main cause of urinary dysfunction.
View Article and Find Full Text PDFA A Pract
August 2024
From the Departments of Anesthesiology and Perioperative Medicine.
Motor-evoked potential (MEP) monitoring is an electrophysiologic technique useful for testing peripheral motor nerve integrity during cryoablation cases with risk of nerve injury. Previously, neuromonitoring within the magnetic resonance imaging (MRI) suite for cryoablation has not been performed as magnetic needles are used which could cause magnetic field interactions with neuromonitoring leads. We present the first report of a patient who underwent MEP monitoring during MRI-guided cryoablation of a vascular malformation adjacent to the brachial plexus.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!