Background: In contrast to bloodstream infection due to a variety of bacteria in patients with cardiovascular implantable electronic devices (CIED), there are limited data regarding candidemia and risk of CIED infection.

Methods: All patients with candidemia and a CIED at Mayo Clinic Rochester between 2012 and 2019 were reviewed. Cardiovascular implantable electronic device infection was defined by (1) clinical signs of pocket site infection or (2) echocardiographic evidence of lead vegetations.

Results: A total of 23 patients with candidemia had underlying CIED; 9 (39.1%) cases were community onset. None of the patients had pocket site infection. The duration between CIED placement and candidemia was prolonged (median 3.5 years; interquartile range, 2.0-6.5). Only 7 (30.4%) patients underwent transesophageal echocardiography and 2 of 7 (28.6%) had lead masses. Only the 2 patients with lead masses underwent CIED extraction, but device cultures were negative for species. Two (33.3%) of 6 other patients who were managed as candidemia without device infection subsequently developed relapsing candidemia. Cardiovascular implantable electronic device removal was done in both patients and device cultures grew species. Although 17.4% of patients were ultimately confirmed to have CIED infection, CIED infection status was undefined in 52.2%. Overall, 17 (73.9%) patients died within 90 days of diagnosis of candidemia.

Conclusions: Although current international guidelines recommend CIED removal in patients with candidemia, the optimal management strategy remains undefined. This is problematic because candidemia alone is associated with increased morbidity and mortality as seen in this cohort. Moreover, inappropriate device removal or retention can both result in increased patient morbidity and mortality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10326679PMC
http://dx.doi.org/10.1093/ofid/ofad318DOI Listing

Publication Analysis

Top Keywords

cardiovascular implantable
16
implantable electronic
16
patients candidemia
12
patients
11
candidemia
9
cied
9
patients cardiovascular
8
electronic devices
8
current international
8
international guidelines
8

Similar Publications

Immediate breast reconstruction provides breast cancer patients with a valuable opportunity to restore breast shape. However, post-reconstruction breast asymmetry remains a common issue that affects patient satisfaction. This study aims to quantify breast asymmetry after surgery using magnetic resonance imaging (MRI) and assess its impact on both breast satisfaction and overall outcome satisfaction, offering scientific evidence to guide improvements in preoperative evaluation.

View Article and Find Full Text PDF

The need for a permanent pacemaker (PPM) implantation after surgical aortic valve implantation (SAVR) is a recognized postoperative complication, with potentially long-term reduced survival. From 1987 to 2017, 2500 consecutive patients underwent SAVR with a biological valve with or without concomitant procedures such as CABG or mitral valve repair. Mechanical valves or valves in another position were excluded.

View Article and Find Full Text PDF

Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.

View Article and Find Full Text PDF

Background: Utilization of transvenous lead extraction/removal (TLE) for the management of cardiac implantable electronic device (CIED)-associated infective endocarditis (IE) remains low.

Objective: To examine the impact of hospital TLE procedural volume on TLE utilization and outcomes for patients with CIED-associated IE.

Methods: Using the Nationwide Readmissions Database, we evaluated 21,545 admissions for patients (mean age 70, 39% female) with CIEDs hospitalized with IE at TLE centres.

View Article and Find Full Text PDF

Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve.

Circ Cardiovasc Interv

December 2024

Department of Pediatrics, Pediatric Cardiology, Stanford University, Palo Alto, CA. (J.K.Y., L.W., A.C.T., H.C., A.W.R., L.F.P., S.R.C., A.M.D., D.B.M.).

Background: Varying rates of nonsustained ventricular tachycardia (NSVT) have been reported early after transcatheter pulmonary valve replacement (TPVR) with the Harmony valve, but data regarding rhythm outcomes beyond hospital discharge are limited. This study aims to characterize ventricular arrhythmias after Harmony TPVR from implant through mid-term follow-up.

Methods: Ventricular arrhythmia data from postimplant telemetry and follow-up extended rhythm monitoring (ERM) were analyzed after Harmony TPVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!