Objectives: To evaluate the ongoing debate concerning the choice of valve prosthesis for women requiring mitral valve replacement (MVR) and who wish to conceive. Bioprostheses are associated with risk of early structural valve deterioration. Mechanical prostheses require lifelong anticoagulation and carry maternal and fetal risks. Also, the optimal anticoagulation regimen during pregnancy after MVR remains unclear.

Methods: A systematic review and meta-analysis was conducted of studies reporting on pregnancy after MVR. Valve- and anticoagulation-related maternal and fetal risks during pregnancy and 30 days' postpartum were analyzed.

Results: Fifteen studies reporting 722 pregnancies were included. In total, 87.2% of pregnant women had a mechanical prosthesis and 12.5% a bioprosthesis. Maternal mortality risk was 1.33% (95% confidence interval [CI], 0.69-2.56), any hemorrhage risk 6.90% (95% CI, 3.70-12.88). Valve thrombosis risk was 4.71% (95% CI, 3.06-7.26) in patients with mechanical prostheses. 3.23% (95% CI, 1.34-7.75) of the patients with bioprostheses experienced early structural valve deterioration. Of these, the mortality was 40%. Pregnancy loss risk was 29.29% (95% CI, 19.74-43.47) with mechanical prostheses versus 13.50% (95% CI, 4.31-42.30) for bioprostheses. Switching to heparin during the first trimester demonstrated a bleeding risk of 7.78% (95% CI, 3.71-16.31) versus 4.08% (95% CI, 1.17-14.28) for women on oral anticoagulants throughout pregnancy and a valve thrombosis risk of 6.99% (95% CI, 2.08-23.51) versus 2.89% (95% CI, 1.40-5.94). Administration of anticoagulant dosages greater than 5 mg resulted in a risk of fetal adverse events of 74.24% (95% CI, 56.11-98.23) versus 8.85% (95% CI, 2.70-28.99) in ≤5 mg.

Conclusions: A bioprosthesis seems the best option for women of childbearing age who are interested in future pregnancy after MVR. If mechanical valve replacement is preferred, the favorable anticoagulation regimen is continuous low-dose oral anticoagulants. Shared decision-making remains priority when choosing a prosthetic valve for young women.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328972PMC
http://dx.doi.org/10.1016/j.xjon.2023.05.001DOI Listing

Publication Analysis

Top Keywords

mechanical prostheses
12
pregnancy mvr
12
95%
12
valve
9
mitral valve
8
valve prosthesis
8
systematic review
8
review meta-analysis
8
valve replacement
8
risk
8

Similar Publications

[Treatment with TOPS for short femoral stump].

Oper Orthop Traumatol

January 2025

Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.

Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.

Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.

View Article and Find Full Text PDF

Osseointegration for transfemoral amputees: Influence of femur length and implant sizing on bone-implant contact and alignment.

Injury

January 2025

Department of Orthopedic Surgery, McGovern Medical School, UTHealth Science Center at Houston, 5420 West Loop S. Suite 1300, Bellaire, TX, 77401, USA. Electronic address:

Introduction: Clinical data on osseointegration (OI) for limb replacement indicates a concerning increase in mechanical complications after five years post-implantation. Since adequate bone-implant contact and proper implant alignment are critical factors for successful osseointegration, it is essential to identify the factors influencing these outcomes. This study aimed to assess the effects of residual femur length and implant sizing on bone-implant contact and implant alignment.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Introduction: In children, polymethylmethacrylate (PMMA) is a commonly used material for fabrication of dental prostheses, such as obturators, removable space maintainers, habit-breaking appliances, removable orthodontic appliances, and removable partial and complete dentures. Regular cleaning of such prostheses is vital for maintaining the health of the oral tissues as well as the longevity of the prosthesis. The chemical method of disinfection, using different chemical cleansers, is commonly used for cleaning a dental prosthesis.

View Article and Find Full Text PDF

Osteochondral damage, caused by trauma, tumors, or degenerative diseases, presents a major challenge due to the limited self-repair capacity of the tissue. Traditional treatments often result in significant trauma and unpredictable outcomes. Recent advances in bone/cartilage tissue engineering, particularly in scaffold materials and fabrication technologies, offer promising solutions for osteochondral regeneration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!