Modeling premise plumbing systems requires accurate treatment of fixture-specific pressure and flow rate relationships. Each fixture in a building may experience different flow rates based on variable service pressure, its unique pressure-flow behavior, and demands throughout the building. Unique experimentally derived pressure-flow parameters for four faucets, a shower/tub fixture, and toilet were developed. The Water Network Tool for Resilience (WNTR) was also used to explore the impact of premise plumbing systems on water distribution systems through two simple skeletonization cases. Minimum pressures for nodes in water distribution system models that represent demand aggregated premise plumbing systems will likely be non-zero and must capture additional pressure drop or elevation differences at the building scale and associated components, such as water meters or backflow preventers. Results showed that flow rates are impacted by pressure in these systems in complex ways, and usage and system characteristics must be considered to be modeled accurately.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324559 | PMC |
http://dx.doi.org/10.1002/aws2.1344 | DOI Listing |
J Appl Microbiol
January 2025
University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box 1627, FI-70211 Kuopio, Finland.
Aims: We investigated the combined effects of pipe materials and disinfection chemicals on bacterial community and its active RNA fraction in water and biofilms in a pilot-scale premise plumbing system.
Methods And Results: The changes in bacterial communities were studied within four pipelines using copper and cross-linked polyethylene (PEX) pipe with chlorine or chloramine disinfection. The total and active bacterial communities and the presence of opportunistic pathogens (Legionella spp.
J Water Health
December 2024
US Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA.
Hot water systems are the most frequent environment associated with the prevalence and growth of opportunistic premise plumbing pathogens (OPPPs). Previous studies identified water heaters as a source of waterborne diseases and concluded that design variables may contribute to their prevalence. A multifaceted approach was used to investigate the vertical stratification of the microbiome and selected OPPPs in an electric water heater tank connected to a home plumbing system simulator.
View Article and Find Full Text PDFAppl Environ Microbiol
December 2024
Environmental Protection Agency, Office of Research and Development, Center for Environmental Solutions and Emergency Response, Cincinnati, Ohio, USA.
(Lp) is an opportunistic drinking water pathogen that can cause infections through the inhalation of Lp-containing aerosols and can occur in premise plumbing systems. In this work, the use of copper (Cu) and silver (Ag) ions was evaluated at the bench and pilot scale to determine (i) the effective independent concentrations of copper and silver that are efficacious in inactivating Lp, (ii) the impact of various water quality parameters on the efficaciousness of copper and silver ions, and (iii) the effectiveness and practicality of using dissociation to produce ions at the pilot scale. At the bench scale, it was determined that 0.
View Article and Find Full Text PDFChemosphere
November 2024
Key Laboratory of Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, School of Environment, Henan Normal University, 46 East of Construction Road, Xinxiang, 453007, China. Electronic address:
It is highly anticipated that efforts will be made to raise the level of industrial effluent reclamation on the background of continuously minimizing waste stream based on preconcentration tool. For this purpose, a triple-doped nanocomposite (TFN-tri) membrane through partially alternative doping spiro-structured 2,2'-dimethyl-1,1'-biphenyl-4,4'-diamine dihydrochloride and flexible 4,4'-bipiperidyl dihydrochloride and continuous incorporating of molybdenum disulfide quantum dots was successfully fabricated. With the assistance of self-synthesized biodegradable flocculant pretreatment, raw hairwork dyeing effluent (HDE) was stably recycled up to 95.
View Article and Find Full Text PDFWater Res
January 2025
Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO 63112, United States.
In response to stresses on water demands, some regions augment conventional drinking water sources with alternative water supplies such as desalinated seawater and reclaimed wastewater. The advanced treatment of wastewater by reverse osmosis, microfiltration, and advanced oxidation processes can produce high quality water for potable uses. However, if not appropriately stabilized, the resulting water can be corrosive to metal-based distribution pipes and plumbing materials.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!