Recent neutron scattering experiments suggested that frustrated magnetic interactions give rise to antiferromagnetic spiral and fractional skyrmion lattice phases in MnSc[Formula: see text]S[Formula: see text] . Here, to trace the signatures of these modulated phases, we studied the spin excitations of MnSc[Formula: see text]S[Formula: see text] by THz spectroscopy at 300 mK and in magnetic fields up to 12 T and by broadband microwave spectroscopy at various temperatures up to 50 GHz. We found a single magnetic resonance with frequency linearly increasing in field. The small deviation of the Mn[Formula: see text] ion g-factor from 2, g = 1.96, and the absence of other resonances imply very weak anisotropies and negligible contribution of higher harmonics to the spiral state. The significant difference between the dc magnetic susceptibility and the lowest-frequency ac susceptibility in our experiment implies the existence of mode(s) outside of the measured frequency windows. The combination of THz and microwave experiments suggests a spin gap opening below the ordering temperature between 50 GHz and 100 GHz.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10329720PMC
http://dx.doi.org/10.1038/s41598-023-37911-6DOI Listing

Publication Analysis

Top Keywords

mnsc[formula text]s[formula
12
magnetic resonance
8
broadband magnetic
4
resonance spectroscopy
4
spectroscopy mnsc[formula
4
text]s[formula text]
4
text] neutron
4
neutron scattering
4
scattering experiments
4
experiments suggested
4

Similar Publications

Sulfur-bridged bonds enabled structure modulation and space confinement of MnS for superior sodium-ion capacitors.

J Colloid Interface Sci

June 2024

School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, PR China; Henan Institute of Advanced Technology, Zhengzhou University, Zhengzhou 450001, PR China. Electronic address:

Manganese sulfide (MnS) is a promising converion-type anode for sodium storage, owing to the virtues of high theoretical capacity, coupled with it crustal abundance and cost-effectiveness. Nevertheless, MnS suffers from inadequate electronic conductivity, sluggish Na reaction kinetics and considerable volume variation during discharge/charge process, thereby impeding its rate capability and capacity retention. Herein, a novel lamellar heterostructured composite of Fe-doped MnS nanoparticles/positively charged reduced graphene oxide (Fe-MnS/PG) was synthesized to overcome these issues.

View Article and Find Full Text PDF

Complexity of quantum phases of matter is often understood theoretically by using gauge structures, as is recognized by the [Formula: see text] and U(1) gauge theory description of spin liquids in frustrated magnets. Anomalous Hall effect of conducting electrons can intrinsically arise from a U(1) gauge expressing the spatial modulation of ferromagnetic moments or from an SU(2) gauge representing the spin-orbit coupling effect. Similarly, in insulating ferro and antiferromagnets, the magnon contribution to anomalous transports is explained in terms of U(1) and SU(2) fluxes present in the ordered magnetic structure.

View Article and Find Full Text PDF

The association between GD and cancer has been uncertain due to ascertainment bias in previously published studies. We analyzed cancer incidence using the Maccabi Healthcare Service (MHS) electronic health records among 264 patients with GD compared to 3440 matched controls. We ascertained cancers diagnosed before and after the index date (i.

View Article and Find Full Text PDF

Transfusion Practice: Hemolysis Markers After In Vitro Infusion of Packed Red Blood Cells by the Gravitational Method in Peripheral Catheter.

J Infus Nurs

November 2023

Nursing School, Universidade Federal de São Paulo, São Paulo, Brazil (Drs Kita, Orsi, de Souza, and Avelar); Department of Biostatistics, Universidade Estadual Paulista Júlio de Mesquita Filho - Botucatu, São Paulo, Brazil (Dr Tsunemi).

The objective of this study was to compare hemolysis marker levels after in vitro infusion of red blood cells (RBCs) according to storage time, infusion rate, and peripheral intravenous catheter size. This is an experimental study with randomly administered RBCs in quintuplicate, according to storage time shorter than and longer than 14 days, as well as infusion rate (50 mL/h and 100 mL/h) using catheters with calibers of 14-, 18-, and 20-gauge. Aliquots were collected from RBCs (V1), after equipment and catheter (V2) free-flow filling and after controlled infusion through the catheter (V3).

View Article and Find Full Text PDF

Mitotic Nuclei Segmentation and Classification Using Chaotic Butterfly Optimization Algorithm with Deep Learning on Histopathology Images.

Biomimetics (Basel)

October 2023

Department of Information Technology, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

Histopathological grading of the tumors provides insights about the patient's disease conditions, and it also helps in customizing the treatment plans. Mitotic nuclei classification involves the categorization and identification of nuclei in histopathological images based on whether they are undergoing the cell division (mitosis) process or not. This is an essential procedure in several research and medical contexts, especially in diagnosis and prognosis of cancer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!