Wearable High Voltage Compliant Current Stimulator for Restoring Sensory Feedback.

Micromachines (Basel)

Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D'Armi, 09123 Cagliari, Italy.

Published: March 2023

Transcutaneous Electrical Nerve Stimulation (TENS) is a promising technique for eliciting referred tactile sensations in patients with limb amputation. Although several studies show the validity of this technique, its application in daily life and away from laboratories is limited by the need for more portable instrumentation that guarantees the necessary voltage and current requirements for proper sensory stimulation. This study proposes a low-cost, wearable high-voltage compliant current stimulator with four independent channels based on Components-Off-The-Shelf (COTS). This microcontroller-based system implements a voltage-current converter controllable through a digital-to-analog converter that delivers up to 25 mA to load up to 3.6 kΩ. The high-voltage compliance enables the system to adapt to variations in electrode-skin impedance, allowing it to stimulate loads over 10 kΩ with currents of 5 mA. The system was realized on a four-layer PCB (115.9 mm × 61 mm, 52 g). The functionality of the device was tested on resistive loads and on an equivalent skin-like RC circuit. Moreover, the possibility of implementing an amplitude modulation was demonstrated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143515PMC
http://dx.doi.org/10.3390/mi14040782DOI Listing

Publication Analysis

Top Keywords

compliant current
8
current stimulator
8
wearable high
4
high voltage
4
voltage compliant
4
stimulator restoring
4
restoring sensory
4
sensory feedback
4
feedback transcutaneous
4
transcutaneous electrical
4

Similar Publications

Importance: Endocrine treatments, such as Tamoxifen (TAM) and/or Aromatase inhibitors (AI), are the adjuvant therapy of choice for hormone-receptor positive breast cancer. These agents are associated with menopausal symptoms, adversely affecting drug compliance. Topical estrogen (TE) has been proposed for symptom management, given its' local application and presumed reduced bioavailability, however its oncological safety remains uncertain.

View Article and Find Full Text PDF

The world population is aging. Comprehensive Geriatric assessment (CGA) has been proven to improve the well-being of older adults. However, evidence suggests not all clinicians implement these recommendations in their practice; nor do all patients adhere to them.

View Article and Find Full Text PDF

Background: Diabetes mellitus (DM) is a global health problem. Adherence to intensive insulin therapy is necessary to achieve better glycemic control in types 1 and 2 DM. This study aimed to evaluate the extent of adherence to insulin therapy, its predictors and to identify barriers to its adherence.

View Article and Find Full Text PDF

Fungal keratitis is a severe ocular infection caused by pathogenic fungi, leading to potential vision loss if untreated. Current antifungal treatments face limitations such as low solubility, poor corneal penetration, and limited therapeutic options. This study aimed to develop a thermosensitive in situ gel incorporating ketoconazole nanoparticles (NPs) to enhance drug solubility, stability, and antifungal activity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!