A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Method for Using IMU-Based Experimental Motion Data in BVH Format for Musculoskeletal Simulations via OpenSim. | LitMetric

Biomechanical simulation allows for in silico estimations of biomechanical parameters such as muscle, joint and ligament forces. Experimental kinematic measurements are a prerequisite for musculoskeletal simulations using the inverse kinematics approach. Marker-based optical motion capture systems are frequently used to collect this motion data. As an alternative, IMU-based motion capture systems can be used. These systems allow flexible motion collection without nearly any restriction regarding the environment. However, one limitation with these systems is that there is no universal way to transfer IMU data from arbitrary full-body IMU measurement systems into musculoskeletal simulation software such as OpenSim. Thus, the objective of this study was to enable the transfer of collected motion data, stored as a BVH file, to OpenSim 4.4 to visualize and analyse the motion using musculoskeletal models. By using the concept of virtual markers, the motion saved in the BVH file is transferred to a musculoskeletal model. An experimental study with three participants was conducted to verify our method's performance. Results show that the present method is capable of (1) transferring body dimensions saved in the BVH file to a generic musculoskeletal model and (2) correctly transferring the motion data saved in the BVH file to a musculoskeletal model in OpenSim 4.4.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303752PMC
http://dx.doi.org/10.3390/s23125423DOI Listing

Publication Analysis

Top Keywords

motion data
16
bvh file
16
saved bvh
12
musculoskeletal model
12
motion
9
musculoskeletal simulations
8
motion capture
8
capture systems
8
musculoskeletal
7
data
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!