A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of Preoperative CT Scans and Patient-Specific Instrumentation May Not Improve Short-Term Adverse Events After Shoulder Arthroplasty: Results from a Large Integrated Health-Care System. | LitMetric

Unlabelled: Ongoing innovation leads to a continuous influx of new technologies related to shoulder arthroplasty. These are made available to surgeons and marketed to both health-care providers and patients with the hope of improving outcomes. We sought to evaluate how preoperative planning technologies for shoulder arthroplasty affect outcomes.

Methods: This was a retrospective cohort study conducted using data from an integrated health-care system's shoulder arthroplasty registry. Adult patients who underwent primary elective anatomic or reverse total shoulder arthroplasty (2015 to 2020) were identified. Preoperative planning technologies were identified as (1) a computed tomography (CT) scan and (2) patient-specific instrumentation (PSI). Multivariable Cox regression and logistic regression were used to compare the risk of aseptic revision and 90-day adverse events, respectively, between procedures for which technologies were and were not used.

Results: The study sample included 8,117 procedures (in 7,372 patients) with an average follow-up of 2.9 years (maximum, 6 years). No reduction in the risk of aseptic revision was observed for patients having either preoperative CT scans (hazard ratio [HR] = 1.22; 95% confidence interval [CI] = 0.87 to 1.72) or PSI (HR = 1.44; 95% CI = 0.71 to 2.92). Patients having CT scans had a lower likelihood of 90-day emergency department visits (odds ratio [OR] = 0.84; 95% CI = 0.73 to 0.97) but a higher likelihood of 90-day venous thromboembolic events (OR = 1.79; 95% CI = 1.18 to 2.74). Patients with PSI use had a higher likelihood of 90-day deep infection (OR = 7.74; 95% CI = 1.11 to 53.94).

Conclusions: We found no reduction in the risk of aseptic revision with the use of these technologies. Patients having CT scans and PSI use had a higher likelihood of venous thromboembolism and deep infection, respectively. Ongoing research with extended follow-up is being conducted to further examine the effects of these technologies on patient outcomes.

Level Of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319369PMC
http://dx.doi.org/10.2106/JBJS.OA.22.00139DOI Listing

Publication Analysis

Top Keywords

shoulder arthroplasty
20
risk aseptic
12
aseptic revision
12
likelihood 90-day
12
higher likelihood
12
preoperative scans
8
patient-specific instrumentation
8
adverse events
8
integrated health-care
8
technologies shoulder
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!