Unlabelled: Lack of a reliable reference standard for carpal tunnel syndrome (CTS) diagnosis could impact the diagnostic test characteristics. This systematic review sought to evaluate differences in the accuracy of CTS diagnostic modalities based on the reference standard used.
Methods: A systematic review was performed following PRISMA guidelines to investigate diagnostic modalities used in CTS. A literature search of Embase, PubMed, and Cochrane Reviews was conducted for the years of 2010-2021 for primary data, and 113 studies met final inclusion criteria. Studies were stratified based on the reference standard utilized and diagnostic modality assessed, and the weighted means of the sensitivities and specificities were calculated.
Results: Thirty-five studies used clinical diagnosis alone as a reference standard, and 78 studies used electrodiagnostic study (EDS). The specificity for MRI and ultrasound (US) were substantially lower when EDS was used as the reference standard. MRI was the test most affected by the reference standard used, showing increased sensitivity when using EDS as the reference compared to clinical diagnosis (77.1% versus 60.9%) and decreased specificity (87.6% versus 99.2%). Regardless of the reference standard used, all tests had anticipated false-positive and/or false-negative rates of at least 10%.
Conclusions: Testing characteristics vary greatly based on the choice of reference standard, with the sensitivity of MRI most affected. Regardless of reference standard used, EDS, US, and MRI each had false-positive and/or false-negative rates too great to be appropriate for use as a screening examination.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317486 | PMC |
http://dx.doi.org/10.1097/GOX.0000000000005067 | DOI Listing |
Eur Thyroid J
January 2025
G Treglia, Repubblica e Cantone Ticino Ente Ospedaliero Cantonale, Bellinzona, Switzerland.
Background: In relapsing differentiated thyroid cancer (DTC), the in vivo evaluation of natrium-iodine symporter (NIS) expression is pivotal in the therapeutic planning and is achieved by [131/123I]Iodine whole-body scan. However, these approaches have low sensitivity due to the low sensitivity due to the low resolution of SPECT. [18F]Tetrafluoroborate (TFB) has been proposed as a viable alternative, which could outperform [131/123I]Iodine scans owing to the superior PET resolution.
View Article and Find Full Text PDFPLoS Negl Trop Dis
January 2025
Centro de Investigaciones Epidemiológica y Salud Pública (CIESP-IECS) CONICET.
Background: Trypanosoma cruzi is a protozoan parasite which causes Chagas disease. Mother-to-child transmission is the main route of transmission in vector-free areas. Congenital Chagas disease refers specifically to cases arising from this route of transmission.
View Article and Find Full Text PDFEJNMMI Res
January 2025
Department of Nuclear Medicine, University Hospital of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
Background: In clinical practice, several radiopharmaceuticals are used for PSMA-PET imaging, each with distinct biodistribution patterns. This may impact treatment decisions and outcomes, as eligibility for PSMA-directed radioligand therapy is usually assessed by comparing tumoral uptake to normal liver uptake as a reference. In this study, we aimed to compare tracer uptake intraindividually in various reference regions including liver, parotid gland and spleen as well as the respective tumor-to-background ratios (TBR) of different F-labeled PSMA ligands to today's standard radiopharmaceutical Ga-PSMA-11 in a series of patients with biochemical recurrence of prostate cancer who underwent a dual PSMA-PET examination as part of an individualized diagnostic approach.
View Article and Find Full Text PDFJ Nephrol
January 2025
Department of Diabetology, Endocrinology, Nephrology, University of Tuebingen, Tuebingen, Germany.
Background: The estimation of glomerular filtration rate (eGFR) is essential in the early detection of diabetic nephropathy. We herein compare the performance of common eGFR formulas against a gold standard measurement of GFR in patients with diabetes mellitus.
Methods: GFR was measured in 93 patients with diabetes mellitus using iohexol clearance as the reference standard.
Insights Imaging
January 2025
Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.
Objectives: To investigate the image quality and diagnostic performance with ultra-low dose dual-layer detector spectral CT (DLSCT) by various reconstruction techniques for evaluation of pulmonary nodules.
Materials And Methods: Between April 2023 and December 2023, patients with suspected pulmonary nodules were prospectively enrolled and underwent regular-dose chest CT (RDCT; 120 kVp/automatic tube current) and ultra-low dose CT (ULDCT; 100 kVp/10 mAs) on a DLSCT scanner. ULDCT was reconstructed with hybrid iterative reconstruction (HIR), electron density map (EDM), and virtual monoenergetic images at 40 keV and 70 keV.