A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the impact of various finish line designs and occlusal morphologies on the accuracy of digital impressions. | LitMetric

Background/purpose: Recent advancements in dental technology has led clinicians to convert from traditional methods to digital workflows. The purpose of this study was to analyze the effect of various finish line designs and occlusal morphologies on the accuracy of digital impressions.

Materials And Methods: Six maxillary molar crown preparations were designed by using a digital sculpting software program. The samples differed in finish line design and occlusal surface morphology. Three different finish line designs (shoulder, chamfer, and shoulder with internal round angle) and two different occlusal morphologies (sharp and rounded) were used, giving six groups. Using three different intraoral scanners, each group was scanned and compared with a reference scan obtained from an industrial scanner. The accuracy of each scan was studied, and the data were statistically analyzed.

Results: A total of 180 scans were acquired by utilizing three different intraoral scanners. The reference scan was compared with the scans from each group and overall differences (marginal, axial, and occlusal) were assessed. A crown preparation with a chamfer finish line showed the lowest marginal discrepancy of 13.2 ± 4.18 μm while preparation with a shoulder finish line reported the highest discrepancy of 34.8 ± 7.9 μm ( < 0.05). Also, the occlusal discrepancies of the samples with rounded and sharp occlusal morphologies were 12.55 ± 3.09 μm and 19.13 ± 2.3 μm, respectively ( < 0.05).

Conclusion: It has been suggested that chamfer finish line design and rounded occlusal anatomy may produce more accurate digital impression for single crown restorations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10316503PMC
http://dx.doi.org/10.1016/j.jds.2023.02.017DOI Listing

Publication Analysis

Top Keywords

finish designs
12
occlusal morphologies
12
designs occlusal
8
morphologies accuracy
8
accuracy digital
8
three intraoral
8
intraoral scanners
8
reference scan
8
finish
6
occlusal
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!