A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modification to the placement of the navigation reference frame in posterior corrective fusion of spinal deformity with myelomeningocele: a series of 6 cases. | LitMetric

To show a modified placement of the navigation reference frame in posterior corrective fusion of spinal deformity with myelomeningocele. This was a retrospective, single-surgeon case series, and IRB-approved study. Six consecutive patients (one male and five females) who were diagnosed with spinal deformity with myelomeningocele underwent posterior corrective fusion surgery from the upper thoracic spine to the pelvis with preoperative computed tomography navigation (pCTN). At the level of the spina bifida, where posterior elements such as the spinous process were missing, the reference frame of the pCTN was placed on the flipped lamina or pedicles, and a pedicle screw (PS) or iliac screw (IS) was inserted. Screw deviation was investigated by using postoperative CT. A total of 55 screws were placed at the spina bifida level and pelvis. Of these, 12 ISs were placed on each side in each case. The screws placed using the pCTN were not reinserted or removed intraoperatively or postoperatively. However, only one PS was found to have perforated the spinal canal on postoperative CT but was left in place because it caused no neurological problem. By modifying the placement of the reference frame, such as placing it on the flipped lamina or pedicles, pCTN could be used even at the levels of the spina bifida, where the posterior elements are missing, to accurately place PSs and various types of ISs.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPB.0000000000001108DOI Listing

Publication Analysis

Top Keywords

reference frame
16
posterior corrective
12
corrective fusion
12
spinal deformity
12
deformity myelomeningocele
12
spina bifida
12
placement navigation
8
navigation reference
8
frame posterior
8
fusion spinal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!