Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets.

Eur J Radiol

Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany; Institute for Radiology, DONAUISAR Hospital Deggendorf-Dingolfing-Landau, Perlasberger Str. 41, 94469 Deggendorf, Germany; Medical Faculty, Ludwig Maximilian University Munich, Bavariaring 19, 80336 Munich, Germany. Electronic address:

Published: August 2023

Purpose: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation.

Methods: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx).

Results: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts.

Conclusion: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2023.110946DOI Listing

Publication Analysis

Top Keywords

posterior spinal
12
artifact reduction
8
spinal fixation
8
photon-counting detector
8
vmi reconstructions
8
reconstructions derived
8
spectral metal
4
metal artifact
4
reduction posterior
4
fixation photon-counting
4