A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The history of the development of the regular straight stem in hip arthroplasty. | LitMetric

Since the middle of the 20th century, total hip arthroplasty has become a very successful treatment for all end-stage diseases of the hip joint. Charnley solved with his low frictional torque arthroplasty the problem of wear and friction with the introduction of a new bearing couple and the reduction of the head size, which set the prerequisite for the further development of stem design. This narrative review presents the major developments of regular straight stems in hip arthroplasty. It does not only provide an overview of the history but also assembles the generally scarce documentation available regarding the rationale of developments and illustrates often-unsuspected links. Charnley's success is based on successfully solving the issue of fixation of the prosthetic components to the bone, using bone cement made of polymethyl-methacrylate. In the field of cemented anchorage of the stem, two principles showing good long-term revision rates emerged over the years: the force-closed and the shape-closed principles. The non-cemented anchorage bases on prosthesis models ensure enough primary stability for osteointegration of the implant to occur. For bone to grow onto the surface, not only sufficient primary stability is required but also a suitable surface structure together with a biocompatible prosthetic material is also necessary.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321046PMC
http://dx.doi.org/10.1530/EOR-22-0122DOI Listing

Publication Analysis

Top Keywords

hip arthroplasty
12
regular straight
8
primary stability
8
history development
4
development regular
4
straight stem
4
hip
4
stem hip
4
arthroplasty
4
arthroplasty middle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!