Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: Linear lesions are routinely created by radiofrequency catheter ablation. Unwanted electrical conduction gaps can be produced and are often difficult to ablate. This study aimed to clarify the characteristics of conduction gaps during atrial fibrillation ablation by analysing bidirectional activation maps using a high-density mapping system (RHYTHMIA).
Methods And Results: This retrospective study included 31 patients who had conduction gaps along pulmonary vein (PV) isolation or box ablation lesions. Activation maps were sequentially created during pacing from the coronary sinus and PV to reveal the earliest activation site, defined by the entrance and exit. The locations, length between the entrance and exit (gap length), and direction were analysed. Thirty-four bidirectional activation maps were drawn: 21 were box isolation lesions (box group), and 13 were PV isolation lesions (PVI group). Among the box group, nine conduction gaps were present in the roof region and 12 in the bottom region, while nine in right PV and four in left PV among the PVI group. Gap lengths in the roof region were longer than those in the bottom region (26.8 ± 11.8 vs. 14.5 ± 9.8 mm; P = 0.022), while those in right PV tended to longer than those in left PV (28.0 ± 15.3 vs. 16.8 ± 8.0 mm, P = 0.201).
Conclusion: The entrances and exits of electrical conduction gaps were separated, especially in the roof region, indicating that epicardial conduction might contribute to gap formation. Identifying the bidirectional conduction gap might indicate the location and direction of epicardial conduction.