A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mid-infrared carbon isotope spectrum logging system combined with a thermostat of optical subsystem for high-precision detection of isotope ratio. | LitMetric

In the process of oil and gas exploration and development, carbon isotope ratio can reflect the maturity of oil and gas and predict the recovery factor, and the isotope ratio in the composition of shale gas is particularly important. Thus, a carbon isotope spectrum logging system was designed and exploited based on tunable diode laser absorption spectroscopy (TDLAS) technology under the fundamental frequency absorption band of CO and CO molecules, and a quantum cascade laser (QCL) with center wavelength of 4.35 μm was applied. For further detection sensitivity, wavelength modulation spectroscopy (WMS) technology was combined to suppress background noise through the modulation of QCL. A multi-pass gas cell (MPGC) with an optical path length of 41 m was utilized for lower limit of detection (LoD). In order to suppress the temperature dependence of the absorption spectrum, the optical subsystem was placed in a high-precision thermostat to maintain a stable temperature, so as to achieve high-precision and high-stability detection. Meanwhile, sparrow search algorithm-back propagation (SSA-BP) was applied for concentration prediction of CO and CO. Taking advantage of the excellent optimization ability, fast convergence speed and high stability of SSA, the problem that BP neural network algorithm is highly dependent on initial value can be solved to some extent. Sensor performance was validated through calibration and stability experiments. The LoD of CO reached a minimum of 0.618 parts-per-billion (ppb) with an 88 s averaging time, and the LoD of CO reached 0.181 ppb when the averaging time was 96 s. Besides, the standard deviation of carbon isotope ratio obtained by this system was ∼ 0.61 ‰. The results illustrate that this self-developed sensor has a bright prospect in the field of shale gas isotope detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123051DOI Listing

Publication Analysis

Top Keywords

carbon isotope
16
isotope ratio
16
isotope spectrum
8
spectrum logging
8
logging system
8
optical subsystem
8
subsystem high-precision
8
oil gas
8
shale gas
8
lod reached
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!