Contemporary gravitational-wave detectors are fundamentally limited by thermal noise-due to dissipation in the mechanical elements of the test mass-and quantum noise-from the vacuum fluctuations of the optical field used to probe the test-mass position. Two other fundamental noises can in principle also limit sensitivity: test-mass quantization noise due to the zero-point fluctuation of its mechanical modes and thermal excitation of the optical field. We use the quantum fluctuation-dissipation theorem to unify all four noises. This unified picture shows precisely when test-mass quantization noise and optical thermal noise can be ignored.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.130.241401 | DOI Listing |
Sensors (Basel)
November 2024
Center for Gravitational Wave Experiment, National Microgravity Laboratory, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China.
Since Einstein's prediction regarding the existence of gravitational waves was directly verified by the ground-based detector Advanced LIGO, research on gravitational wave detection has garnered increasing attention. To overcome limitations imposed by ground vibrations and interference at arm's length, a space-based gravitational wave detection initiative was proposed, which focuses on analyzing a large number of waves within the frequency range below 1 Hz. Due to the weak signal intensity, the TMs must move along their geodesic orbit with a residual acceleration less than 10 m/s/Hz.
View Article and Find Full Text PDFRev Sci Instrum
December 2024
Faculty of Physics, Lomonosov Moscow State University, 119991 Moscow, Russia.
High purity silicon is considered as the test mass material for future cryogenic gravitational-wave detectors, in particular Einstein Telescope-low frequency and LIGO Voyager [(LIGO) Laser Interferometer Gravitational-Wave Observatory]. To reduce the thermal noise of the test masses, it is necessary to study the sources of corresponding losses. Mechanical resonators with frequencies 300 Hz-6 kHz are successfully used for studying, for example, losses in optical coatings of the test mass.
View Article and Find Full Text PDFPLoS One
October 2024
School of Electronic Information Engineering, Changchun University of Science and Technology, Changchun, China.
During the process of detecting gravitational waves in space, addressing noise issues caused by terrestrial vibrations, natural environmental changes, and the factors intrinsic to the detectors, this paper proposes a multiscale variational mode adaptive denoising algorithm based on momentum gradient descent. This algorithm integrates momentum factors and multiscale concepts into the variational mode algorithm to resolve the issue of multiple local optima encountered during operation, reduce oscillations in regions with large or unstable gradient changes, and improve convergence speed. Additionally, the algorithm combines the least mean squares algorithm to automatically adjust weights, thereby mitigating the impact of noise, addressing the issue of noise from multiple and random sources, effectively suppressing noise in the gravitational wave signal, and enhancing the quality and reliability of the gravitational wave signal.
View Article and Find Full Text PDFNat Astron
August 2024
Center for Theoretical Astrophysics and Cosmology, Institute for Computational Science, University of Zurich, Zurich, Switzerland.
The most massive black holes in our Universe form binaries at the centre of merging galaxies. The recent evidence for a gravitational-wave (GW) background from pulsar timing may constitute the first observation that these supermassive black-hole binaries (SMBHBs) merge. Yet, the most massive SMBHBs are out of reach of interferometric GW detectors and are exceedingly difficult to resolve individually with pulsar timing.
View Article and Find Full Text PDFGround-based laser interferometric gravitational wave detectors (GWDs) consist of multiple optical cavity systems whose lengths need to be interferometrically controlled. An arm-length stabilization (ALS) system has played an important role in bringing these interferometers into an operational state and enhancing their duty cycle. The sensitivity of these detectors can be improved if the thermal noise of their test mass mirror coatings is reduced.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!