Background: Swimmers commonly access performance metrics such as lap splits, distance, and pacing information between work bouts while they rest. Recently, a new category of tracking devices for swimming was introduced with the FORM Smart Swim Goggles (FORM Goggles). The goggles have a built-in see-through display and are capable of tracking and displaying distance, time splits, stroke, and pace metrics in real time using machine learning and augmented reality through a heads-up display. The purpose of this study was to assess the validity and reliability of the FORM Goggles compared with video analysis for stroke type, pool length count, pool length time, stroke rate, and stroke count in recreational swimmers and triathletes.
Method: A total of 36 participants performed mixed swimming intervals in a 25-m pool across two identical 900-m swim sessions performed at comparable intensities with 1 week interval. The participants wore FORM Goggles during their swims, which detected the following five swim metrics: stroke type, pool length time, pool length count, stroke count, and stroke rate. Four video cameras were positioned on the pool edges to capture ground truth video footage, which was then manually labeled by three trained individuals. Mean (SD) differences between FORM Goggles and ground truth were calculated for the selected metrics for both sessions. The absolute mean difference and mean absolute percentage error were used to assess the differences of the FORM Goggles relative to ground truth. The test-retest reliability of the goggles was assessed using both relative and absolute reliability metrics.
Results: Compared with video analysis, the FORM Goggles identified the correct stroke type at a rate of 99.7% ( = 2,354 pool lengths, < 0.001), pool length count accuracy of 99.8%, and mean differences (FORM Goggles-ground truth) for pool length time: -0.10 s (1.49); stroke count: -0.63 (1.82); and stroke rate: 0.19 strokes/min (3.23). The test-retest intra-class correlation coefficient (ICC) values between the two test days were 0.793 for pool length time, 0.797 for stroke count, and 0.883 for stroke rate. Overall, for pool length time, the residuals were within ±1.0s for 65.3% of the total pool lengths, for stroke count within ±1 stroke for 62.6% of the total pool lengths, and for stroke rate within ±2 strokes/min for 66.40% of the total pool lengths.
Conclusion: The FORM Goggles were found valid and reliable for the tracking of pool length time, pool length count, stroke count, stroke rate, and stroke type during freestyle, backstroke, and breaststroke swimming in recreational swimmers and triathletes when compared with video analysis. This opens perspectives for receiving real-time information on performance metrics during swimming.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304285 | PMC |
http://dx.doi.org/10.3389/fspor.2023.1188102 | DOI Listing |
JMIR Form Res
February 2025
Department of Otolaryngology, Mejiro University Ear Institute Clinic, 320 Ukiya, Iwatsuki-ku, Saitama-shi, Saitama, 339-8501, Japan, 81 48-797-3341.
Background: Observing eye movements during episodic vertigo attacks is crucial for accurately diagnosing vestibular disorders. In clinical practice, many cases lack observable symptoms or clear findings during outpatient examinations, leading to diagnostic challenges. An accurate diagnosis is essential for timely treatment, as conditions such as benign paroxysmal positional vertigo (BPPV), Ménière's disease, and vestibular migraine require different therapeutic approaches.
View Article and Find Full Text PDFNurs Crit Care
January 2025
Teaching in Nursing Department, Faculty of Nursing, Akdeniz University, Antalya, Turkey.
Background: The use of virtual reality is increasing in nursing to ensure patient safety and to improve the quality of care in the education of nurses.
Aim: To develop a virtual reality software for intensive care patient care management and to investigate the effect of this software on novice intensive care nurses.
Study Design: This study protocol contains a randomized controlled experimental design research.
JMIR Form Res
January 2025
Scientific Research, SleepScore Labs, 2175 Salk Avenue, Suite 150, Carlsbad, CA, 92008, United States, 1 858-299-8995.
Background: Insufficient sleep is a problem affecting millions. Poor sleep can trigger or worsen anxiety; conversely, anxiety can lead to or exacerbate poor sleep. Advances in innovative consumer products designed to promote relaxation and support healthy sleep are emerging, and their effectiveness can be evaluated accurately using sleep measurement technologies in the home environment.
View Article and Find Full Text PDFThe risk for transmission of highly pathogenic avian influenza A(H5N1) virus from dairy cows to humans is currently low; however, personal protective equipment (PPE) use during work activities on dairy farms has not been well described. PPE use can protect farmworkers when they are working with highly pathogenic avian influenza A(H5N1)-infected cows. The Colorado Department of Public Health and Environment (CDPHE) and the Colorado Department of Agriculture (CDA) offered PPE to all Colorado farms before or during an A(H5N1) outbreak in cows in 2024.
View Article and Find Full Text PDFJ Perianesth Nurs
October 2024
Surgical Medical Sciences, Department of Anesthesiology and Reanimation, Karadeniz Technical University, Trabzon, Turkey.
The decision to undergo surgery and the significance of the operating theater environment are influenced by several factors, which vary from person to person. Negative perceptions of the operating room environment can influence the decision to undergo surgery and the process of treatment. Virtual reality (VR) technology offers the potential to alter individuals' environmental encounters through the provision of diverse environmental perceptions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!