AI Article Synopsis

  • - The study compares the effectiveness of patient-specific 3D printed plates (3DP) versus conventional plates (CP) for reducing complex pelvic bone fractures, analyzing data from 10 cases using 3DP and 5 cases using CP.
  • - Results showed that the 3DP group achieved significantly better reduction with lower vertex distances, length variations, and angular variations compared to the CP group, indicating a more precise fit to the bone.
  • - The findings suggest that using customized 3D printed plates may enhance the accuracy of pelvic fracture reductions, potentially improving surgical outcomes.

Article Abstract

Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fracture models was compared between two groups: the 3D printing plate (3DP) group using a patient-specific 3D printed plate after virtual reduction and the conventional plate (CP) group using a conventional plate by manual bending. The 3DP and CP groups included 10 and 5 cases, respectively. The fractured models were reduced virtually and their non-locking metal plates were customized using 3D printing. The process of contouring the conventional plates to fit the contact surface of the bone with the bending tool was conducted by an experienced pelvic bone trauma surgeon. The reduction and fixation achieved using the two different plate groups was compared, and the significance of differences in the results was analyzed using paired t-tests, after verifying the normality of data distribution. The vertex distances between the surface of the bone and the contact surface of the plate were significantly lower in the 3DP group than in the CP group (0.407 ± 0.342 and 2.195 ± 1.643, respectively, P = 0.008). Length and angular variations, which are measurements of the reduction state, were also lower in the 3DP group than in the CP group (length variation: 3.211 ± 2.497 and 5.493 ± 3.609, respectively, P = 0.051; angular variation: 2.958 ± 1.977 and 4.352 ± 1.947, respectively, P = 0.037). The customized 3D printed plate in the virtual reduction model provided a highly accurate reduction of pelvic bone fractures, suggesting that the customized 3D printed plate may help ensure easy and accurate reduction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310805PMC
http://dx.doi.org/10.1038/s41598-023-37433-1DOI Listing

Publication Analysis

Top Keywords

printed plate
16
pelvic bone
16
customized printed
12
conventional plate
12
3dp group
12
plate
10
reduction
8
plate virtual
8
virtual reduction
8
contact surface
8

Similar Publications

Light-curing of restorative composite through milled and 3D-printed full-contour zirconia for adhesive luting.

Dent Mater

January 2025

KU Leuven, Department of Oral Health Sciences, BIOMAT & UZ Leuven, Dentistry, Kapucijnenvoer 7, 3000 Leuven, Belgium. Electronic address:

Objectives: To evaluate the effect of different zirconia compositions and manufacturing processes on the light irradiance (LI), to measure the degree of conversion (DC) of solely light-curing restorative composite underneath these zirconia grades and to evaluate the respective zirconia microstructures.

Methods: Six dental zirconia grades (GC HT, GC UHT [GC]; Katana HT, Katana UTML [Kuraray Noritake]; Lava Esthetic, Lava Plus [3 M Oral Care]) were cut and sintered per manufacturer instructions. One 3D-printed zirconia grade (XJet [XJET]) was prepared according to previous research.

View Article and Find Full Text PDF

Aim: This report highlights successful management of a rare case of a mandibular premolar with Oehler's Type IIIb Dens Invaginatus (DI) and peri-invagination periodontitis with guided intentional replantation (IR) without root canal treatment.

Methods: A 22-year-old female patient reported with discomfort and a sinus tract associated with tooth #21. Clinical examination and cone beam computed tomography revealed tooth #21 had an Oehler's Type IIIb DI with peri-invagination periodontitis.

View Article and Find Full Text PDF

The fused deposition modeling (FDM) form of additive manufacturing provides a low-cost opportunity to quickly create unique parts with complex geometries using a high degree of precision. This is accomplished through a layer-by-layer extrusion of a metallic infused thermoplastic from a heated nozzle onto a build plate, until the 3D part is achieved. The ability to produce cheaply manufactured FDM printed cast iron parts would allow industries to bypass casting lead times and create custom cast iron parts without a machined mold.

View Article and Find Full Text PDF

The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.

View Article and Find Full Text PDF

Higher interfragmentary compression force improves lateral tibial plateau fracture stability using locking plate fixation: experimental and simulation verification.

BMC Musculoskelet Disord

December 2024

Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, School of Basic Medical Sciences, Southern Medical University, No.1023, South Shatai Road, Baiyun District, Guangzhou, Guangdong, 510515, China.

Background: This study investigated the impact of higher interfragmentary compression force (IFCF) on the stability of locking plate fixation in lateral tibial plateau fractures.

Methods: Biomechanical experiments and finite element analysis (FEA) were employed to compare the performance of the AO cancellous lag screw (AOCLS) and a newly developed combined cancellous lag screw (CCLS).

Results: The results demonstrated that the CCLS provided a higher IFCF without the risk of over-screwing, significantly improving fixation stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?