COVID-19, a pandemic of acute respiratory syndrome diseases, led to significant social, economic, psychological, and public health impacts. It was not only uncontrolled but caused serious problems at the outbreak time. Physical contact and airborne transmission are the main routes of transmission for bioaerosols such as SARS-CoV-2. According to the Centers for Disease Control (CDC) and World Health Organization (WHO), surfaces should be disinfected with chlorine dioxide, sodium hypochlorite, and quaternary compounds, while wearing masks, maintaining social distance, and ventilating are strongly recommended to protect against viral aerosols. Ozone generators have gained much attention for purifying public places and workplaces' atmosphere, from airborne bioaerosols, with specific reference to the COVID-19 pandemic outbreak. Despite the scientific concern, some bioaerosols, such as SARS-CoV-2, are not inactivated by ozone under its standard tolerable concentrations for human. Previous reports did not consider the ratio of surface area to volume, relative humidity, temperature, product of time in concentration, and half-life time simultaneously. Furthermore, the use of high doses of exposure can seriously threaten human health and safety since ozone is shown to have a high half-life at ambient conditions (several hours at 55% of relative humidity). Herein, making use of the reports on ozone physicochemical behavior in multiphase environments alongside the collision theory principles, we demonstrate that ozone is ineffective against a typical bioaerosol, SARS-CoV-2, at nonharmful concentrations for human beings in air. Ozone half-life and its durability in indoor air, as major concerns, are also highlighted in particular.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-023-28402-2DOI Listing

Publication Analysis

Top Keywords

indoor air
8
collision theory
8
covid-19 pandemic
8
bioaerosols sars-cov-2
8
concentrations human
8
relative humidity
8
ozone
6
critical mini-review
4
mini-review challenge
4
challenge gaseous
4

Similar Publications

Background: Coronavirus disease (COVID-19) quickly spread around the world after its initial identification in Wuhan, China in 2019 and became a global public health crisis. COVID-19 related hospitalizations and deaths as important disease outcomes have been investigated by many studies while less attention has been given to the relationship between these two outcomes at a public health unit level. In this study, we aim to establish the relationship of counts of deaths and hospitalizations caused by COVID-19 over time across 34 public health units in Ontario, Canada, taking demographic, geographic, socio-economic, and vaccination variables into account.

View Article and Find Full Text PDF

RADON in a high karst area of Montenegro - A case study.

Appl Radiat Isot

January 2025

School of Applied Mathematics and Informatics, University of Osijek, Trg Ljudevita Gaja 6, Osijek, Croatia.

The national radon surveys in Montenegro revealed that the highest annual average radon concentrations (C) in ground floors of dwellings and schools were found in a rural region characterized as a typical high-karst area. In this region, spanning approximately 800 km, C values in 9 houses and 16 schools ranged from 219 to 2494 Bq/m, with AM = 977 Bq/m. To investigate the causes of these elevated indoor radon concentrations, the following parameters were measured near the 25 surveyed buildings: soil humidity, electrical conductivity, pH, activity concentrations of Ra, U, U, Th and K, radon concentration in soil gas (c), soil permeability for radon gas (k), and gamma dose rate in the air.

View Article and Find Full Text PDF

Maintaining an optimal indoor thermal environment is crucial for enhancing the welfare and productivity of livestock in intensive breeding farms. This paper investigated the application of a combined geothermal heat pump with a precision air supply (GHP-PAS) system for cooling dairy cows on a dairy farm. The effectiveness of the GHP-PAS system in mitigating heat stress in lactating dairy cattle, along with its energy performance and local cooling efficiency in the free stalls were evaluated.

View Article and Find Full Text PDF

Radon, a common radioactive indoor air pollutant, is the second leading cause of lung cancer in the United States. Knowledge about its distribution is essential for risk assessment and designing efficient protective regulations. However, the three current radon maps for the United States are unable to provide the up-to-date, high-resolution, and time-varying radon concentrations.

View Article and Find Full Text PDF

Exposure Contrasts of Women Aged 40-79 Years during the Household Air Pollution Intervention Network Randomized Controlled Trial.

Environ Sci Technol

January 2025

Division of Environmental Health Sciences, School of Public Health, University of California, Berkeley, California 94609, United States.

Exposure to household air pollution has been linked to adverse health outcomes among women aged 40-79. Little is known about how shifting from biomass cooking to a cleaner fuel like liquefied petroleum gas (LPG) could impact exposures for this population. We report 24-h exposures to particulate matter (PM), black carbon (BC), and carbon monoxide (CO) among women aged 40 to <80 years participating in the Household Air Pollution Intervention Network trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!