Using continuous pulse oximetry (cSpO ) to monitor children with bronchiolitis who are not receiving supplemental oxygen is a form of medical overuse. In this longitudinal analysis from the Eliminating Monitor Overuse (EMO) study, we aimed to assess changes in cSpO overuse before, during, and after intensive cSpO -deimplementation efforts in six hospitals. Monitoring data were collected during three phases: "P1" baseline, "P2" active deimplementation (all sites engaged in education and audit and feedback strategies), and "P3" sustainment (a new baseline measured after strategies were withdrawn). Two thousand and fifty-three observations were analyzed. We found that each hospital experienced reductions during active deimplementation (P2), with overall adjusted cSpO overuse decreasing from 53%, 95% confidence interval (CI): (49-57) to 22%, 95% CI: (19-25) between P1 and P2. However, following the withdrawal of deimplementation strategies, overuse rebounded in all six sites, with overall adjusted cSpO overuse increasing to 37%, 95% CI: (33-41) in P3.