The immersed boundary (IB) method is a mathematical framework for fluid-structure interaction problems (FSI) that was originally developed to simulate flows around heart valves. Direct comparison of FSI simulations around heart valves against experimental data is challenging, however, due to the difficulty of performing robust and effective simulations, the complications of modeling a specific physical experiment, and the need to acquire experimental data that is directly comparable to simulation data. Such comparators are a necessary precursor for further formal validation studies of FSI simulations involving heart valves. In this work, we performed physical experiments of flow through a pulmonary valve in an in vitro pulse duplicator, and measured the corresponding velocity field using 4D flow MRI (4-dimensional flow magnetic resonance imaging). We constructed a computer model of this pulmonary artery setup, including modeling valve geometry and material properties via a technique called design-based elasticity, and simulated flow through it with the IB method. The simulated flow fields showed excellent qualitative agreement with experiments, excellent agreement on integral metrics, and reasonable relative error in the entire flow domain and on slices of interest. These results illustrate how to construct a computational model of a physical experiment for use as a comparator.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10775908PMC
http://dx.doi.org/10.1007/s10439-023-03266-2DOI Listing

Publication Analysis

Top Keywords

heart valves
12
immersed boundary
8
simulations heart
8
flow mri
8
fsi simulations
8
experimental data
8
physical experiment
8
simulated flow
8
flow
7
comparison immersed
4

Similar Publications

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Background: Transcatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.

Case Presentation: An 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week.

View Article and Find Full Text PDF

PDA-associated infective endocarditis with pulmonary artery perforation.

Pak J Med Sci

January 2025

Muhammad Ali Mumtaz, MD FACS. Tahir Heart Institute, Fazl-e-Omar Hospital, Chenab Nagar, District Chiniot, Pakistan.

Infective endocarditis used to frequently cause mortality in subjects having PDA before the advent of antibiotics and surgical ligation. It has been documented that clinically silent PDAs may cause infective complications of heart valves. We present case of an 18-years-old male who presented with palpitations and fever to our emergency department.

View Article and Find Full Text PDF

Background And Objectives: Currently, there remains a paucity of research on the deformation and valve function of transcatheter heart valves (THV) in patients with aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR). This study aimed to thoroughly explore the correlation between THV deformation and postoperative hemodynamics in these patients.

Methods: In this study, we assessed 39 AR patients treated with the J-Valve THV system during TAVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!